Page #33 background imageLoading...
Page #33 background image
English
Nautilus
®
CC plus
Nautilus
®
T
33
86066 BA-en/00 357.00001.../ 358.00001...
en
Manual casting with pyrometer
Manual casting with pyrometer is only possible with
Nautilus
®
CC plus.
Manual casting (with pyrometer) is usually only
needed to check and correct preheating and casting
temperatures. For example, this is necessary when
creating programs for non-BEGO alloys (see page
28).
1. Press "Manual casting".
2. Afterwards, press "With pyrometer".
The previously used program is displayed.
3. Confirm with „OK“ - or select a new program by
pressing on the number and entering a new
program number.
(Corrections are possible with the "Arrow" but-
ton. Confirm with
.)
Program number of the required alloy:
see the program tables on pages 27 to 29.
4. Press on the respective button in order to edit.
5. Confirm the alloy and casting temperature with
„OK“ - or change the casting temperature by
pressing on the number and entering a new
casting temperature.
NOTE
Keep it pressed until the pressed button changes.
Longer pressing is required.
NOTE
Only if the protocol is activated (see page 40) in
the basic settings is the data requested now. This
data appears in the casting protocol that is stored
on the connected USB stick.

Other manuals for Bego Nautilus T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bego Nautilus T and is the answer not in the manual?

Bego Nautilus T Specifications

General IconGeneral
BrandBego
ModelNautilus T
CategoryDental equipment
LanguageEnglish

Related product manuals