26 iNUKE NU6000/NU3000/NU1000 Quick Start Guide 27
Specications Especicaciones técnicas
NU6000 NU3000 NU1000
Output Power
Maximum Output Power
Stereo
2 Ω per channel, stereo 2 x 1500 W 2 x 530 W
4 Ω per channel, stereo 2 x 3000 W 2 x 880 W 2 x 310 W
8 Ω per channel, stereo 2 x 1600 W 2 x 440 W 2 x 160 W
Bridged mono
4 Ω 3000 W 1050 W
8 Ω 1520 W 620 W
System
Controls
Front Power switch Gain controls (channels A and B)
Rear
Mode switch (stereo / mono)
Crossover switch (LF / fullrange / HF)
Circuit breaker
Mode switch (bridge / stereo / mono)
Crossover switch (LF / fullrange / HF)
Mode switch (bridge / stereo / mono)
Crossover switch (LF / fullrange / HF)
Indicators
Power Amber/red backlit illuminated gain controls
Limit (per channel) 0 dBFS
Signal (per channel) -24, -12, -6 dBFS
Input Sensitivity
For rated power into 4 Ω 0.775 V (0 dBu) 0.775 V (0 dBu) 0.775 V (0 dBu)
Connectors
Inputs 2 x combo jacks
Input impedance 10 kΩ unbalanced, 20 kΩ balanced
Outputs 2 x locking-style professional speaker connectors
Output circuit type Class-D Class-D Class-D
Distortion, 1/8 rated power <0.1% <0.05% <0.05%
Frequency response 20 Hz to 20 kHz, +0 / -2 dB 20 Hz to 20 kHz, +0 / -1 dB 20 Hz to 20 kHz, +0 / -1 dB
Signal-to-noise >100 dB >100 dB >100 dB
Circuit Protection
Cooling Continuously variable speed fan Back-to-front air ow
Amplier protection Thermal and DC protection Stable into reactive or mismatched loads
Load protection On/o muting, DC-fault power supply shutdown
Power Supply, Voltage, Current Consumption (Breaker / Fuses)
USA / Canada / Japan 100-120 V~, 50/60 Hz, (25 A 250 VAC) 100-120 V~, 50/60 Hz, 1.8 A (T 10 A H 250 V) 100-120 V~, 50/60 Hz, 0.64 A (T 6.3 A H 250 V)
UK / Australia / Europe / Korea / China 220-240 V~, 50/60 Hz, (12 A 250 VAC) 220-240 V~, 50/60 Hz, 0.9 A (T 6.3 A H 250 V) 220-240 V~, 50/60 Hz, 0.32 A (T 3.15 A H 250 V)
Power consumption @ 2 Ω per channel, 1/8 rated power
350 W 150 W
Power consumption @ 4 Ω per channel, 1/8 rated power
560 W 170 W 70 W
Mains connector Standard IEC receptacle
Dimensions / Weight
Dimensions (H x W x D) appr. 89 x 483 x 328 mm (3.5 x 19 x 12.9") appr. 89 x 483 x 248 mm (3.5 x 19 x 9.8") appr. 89 x 483 x 248 mm (3.5 x 19 x 9.8")
Weight appr. 5.3 kg (11.7 lbs) appr. 3 kg (6.6 lbs) appr. 2.8 kg (6.1 lbs)
NU6000 NU3000 NU1000
Potencia de Salida
Máxima Potencia de Salida
Stereo
2 Ω por canal, stereo 2 x 1500 W 2 x 530 W
4 Ω por canal, stereo 2 x 3000 W 2 x 880 W 2 x 310 W
8 Ω por canal, stereo 2 x 1600 W 2 x 440 W 2 x 160 W
Puente mono
4 Ω modo de puente mono 3000 W 1050 W
8 Ω modo de puente mono 1520 W 620 W
Sistema
Controles
Panel frontal Interruptor de encendido control GAIN (canales A y B)
Panel trasero
Mode (bridge / stereo / mono)
Interruptores Crossover (fullrange / 100 Hz)
Disyuntor
Mode (bridge / stereo / mono)
Interruptores Crossover (fullrange / 100 Hz)
Mode (bridge / stereo / mono)
Interruptores Crossover (fullrange / 100 Hz)
Indicadores
Encendido Controles ámbar y rojas sistema de iluminación botón de ganancia
Limitación (por canal) 0 dBFS
Señal (por canal) -24, -12, -6 dBFS
Sensibilidad de Entrada
Para potencia media a 4 Ω 0.775 V (0 dBu) 0.775 V (0 dBu) 0.775 V (0 dBu)
Conectores
Entradas 2 x conectores combo XLR / TRS de 6,3 mm
Impedancia de entrada 10 kΩ no balanceado, 20 kΩ balanceado
Salidas 2 x conectores profesionales de altavoz con seguro
Tipo de circuito de salida Clase-D Clase-D Clase-D
Distorsión <0,1% <0,05% <0,05%
Respuesta de frecuencia 20 Hz - 20 kHz, +0 / -2 dB 20 Hz - 20 kHz, +0 / -1 dB 20 Hz - 20 kHz, +0 / -1 dB
Relación señal-ruido >100 dB >100 dB >100 dB
Circuito de Protección
Refrigeración Ventilador de velocidad variable continuamente Flujo de aire trasero-frontal
Protección del amplicador Protección térmico y DC Estable con cargas reactivas o desparejadas
Protección contra sobrecargas Anulación on/o, apagado en caso de corte de corriente
Alimentación, Voltaje (Disyuntor / Fusibles)
EE.UU. / Canadá / Japón 100-120 V~, 50/60 Hz, (25 A 250 VAC) 100-120 V~, 50/60 Hz, 1.8 A (T 10 A H 250 V) 100-120 V~, 50/60 Hz, 0.64 A (T 6.3 A H 250 V)
Reino Unido / Australia / Europa / Corea / China 220-240 V~, 50/60 Hz, (12 A 250 VAC) 220-240 V~, 50/60 Hz, 0.9 A (T 6.3 A H 250 V) 220-240 V~, 50/60 Hz, 0.32 A (T 3.15 A H 250 V)
Consumo @ 2 Ω, 1/8 de potencia media 350 W 150 W
Consumo @ 4 Ω, 1/8 de potencia media 560 W 170 W 70 W
Toma de corriente Receptáculo IEC standard
Dimensiones / Peso
Dimensiones (A x L x P) aprox. 89 x 483 x 328 mm (3.5 x 19 x 12.9") aprox.89 x 483 x 248 mm (3.5 x 19 x 9.8") aprox. 89 x 483 x 248 mm (3.5 x 19 x 9.8")
Peso aprox. 5,3 kg (11,7 lbs) aprox. 3 kg (6,6 lbs) aprox. 2,8 kg (6,1 lbs)