EasyManua.ls Logo

Beko BP109AH - User Manual

Beko BP109AH
220 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Portable
Air-conditioner
User Manual
EN FR IT NL
BP109C BP112C BP112H
BP113H BP109AC BP109AH

Table of Contents

Questions and Answers

  • M
    michelle91Aug 12, 2025
    Why is my Beko Air Conditioner not cool enough?
    • A
      Aaron PalmerAug 12, 2025
      If your Beko Air Conditioner isn't cooling sufficiently, several factors could be the cause. First, ensure that all doors and windows are completely closed. Eliminate any potential heat sources within the room. Check the exhaust air hose to confirm it's properly connected and free from blockages; clean or reconnect it as necessary. Also, verify that the temperature setting isn't set too high and adjust it accordingly. Finally, inspect the air inlet and clear any obstructions that may be present.
  • S
    sbensonAug 15, 2025
    What to do if my Beko BP109AH does not start?
    • S
      Shari BenjaminAug 15, 2025
      Your Beko Air Conditioner might not start due to several reasons. If the water full indicator lamp is blinking, it means the water tank is full; you should empty it. Also, if you are in heating mode, the room temperature might be higher than the set temperature, or in cooling mode, the room temperature might be lower than the set temperature. In these cases, try resetting the temperature.
  • B
    bwilliamsonAug 20, 2025
    Why is my Beko BP109AH so noisy?
    • L
      Linda HaysAug 20, 2025
      If your Beko Air Conditioner is producing excessive noise, check whether it is placed on an uneven surface. Placing it on a flat, level ground may reduce the noise. Note that some noise is normal, as the sound may come from the refrigerant flowing inside the air conditioner.
  • D
    Derek ThomasAug 23, 2025
    What does E2 code mean on Beko BP109AH Air Conditioner?
    • H
      huffmanjaniceAug 23, 2025
      If your Beko Air Conditioner is showing an E2 error code, it indicates that the water tank is full during cooling. To resolve this, remove the rubber stopper and empty the water.
  • T
    Timothy HolmesAug 27, 2025
    What does E4 code mean on Beko BP109AH Air Conditioner?
    • D
      David CarterAug 27, 2025
      If your Beko Air Conditioner displays an E4 error code, it means the water tank is full when heating. Please empty the water tank to resolve this issue.
  • B
    Brooke MaddoxAug 31, 2025
    What does E0 code mean on Beko BP109AH?
    • K
      Kenneth HodgesAug 31, 2025
      If your Beko Air Conditioner is showing an E0 error code, it indicates a failure of the room temperature sensor. You can replace the room temperature sensor, although the unit can still function without doing so.
  • D
    Darlene HuertaSep 3, 2025
    What does E3 code mean on Beko Air Conditioner?
    • B
      Brianna HessSep 4, 2025
      If your Beko Air Conditioner displays an E3 error code, it means that the evaporator temperature sensor has failed. To fix this, replace the evaporator temperature sensor.
  • W
    williamsmatthewSep 7, 2025
    What does E1 code mean on Beko BP109AH Air Conditioner?
    • R
      rodneyjacksonSep 7, 2025
      If your Beko Air Conditioner is showing an E1 error code, it means the condenser temperature sensor has failed. Replace the condenser temperature sensor to resolve this issue.

Summary

Safety Awareness and Precautions

R290 Refrigerant Safety Precautions

Specific warnings and guidelines for handling appliances with R290 refrigerant gas.

General Safety Instructions

Key directives for safe operation, installation, and maintenance of the air conditioner.

R290 Refrigerant Handling Procedures

Detailed procedures for working with, repairing, and decommissioning units with flammable refrigerants.

Appearance and Function of Control Panel

Remote Control Operation and Display

Operation Introduction

Installation Explanations

Maintenance Explanations

Cleaning the Air Filter

Step-by-step guide for removing, cleaning, and reinstalling the air filter.

General Maintenance and Storage

Troubleshooting Common Issues

Technical Specifications

Beko BP109AH Specifications

General IconGeneral
TypeMonobloc mobile air conditioner
TechnologyAir - air
Timer typeDigital
Noise level65 dB
Climate classT
Number of speeds3
Sound power level48 dB
Airflow (high speed)380 m³/h
Comfort sleeping modeYes
Cooling capacity (max)- BTU/h
Dehumidifying capacity1 l/h
Timer duration (maximum)24 h
Air conditioner functionsCooling, Dehumidifying, Heating
Cooling temperature range7 - 27 °C
Heating temperature range18 - 38 °C
Cooling capacity in watts (max)- W
Cooling capacity in watts (nominal)2500 W
Heating capacity in watts (nominal)2100 W
Cooling energy efficiency (EER, W/W)3.1
Heating energy efficiency (COP, W/W)2.6
AC input voltage220 - 240 V
AC input frequency50 Hz
Energy efficiency scaleA+++ to D
Energy efficiency class (cooling)A+
Annual energy consumption (cooling)- kWh
Hourly energy consumption (cooling)0.9 kWh
Control typeTouch
Display typeLCD
Product colorWhite
Weight and Dimensions IconWeight and Dimensions
Depth335 mm
Width440 mm
Height715 mm
Weight28500 g
Package depth376 mm
Package width474 mm
Package height885 mm
Package weight32000 g