DURAFLO™ 18 GPM PUMPING STATIONS
1MANUL375
Belanger, Inc.® * PO BOX 5470 * Northville, MI 48167-5470* Ph (248) 349-7010 * Fax (248) 380-9681
27
Maintenance
Pumping Station Float Valve Seal Replacement Kit (#105884)
Removing the Existing Stem Assembly
3) Remove the valve from the Bulkhead fitting on the tank.
4) Remove the two upper pins and Cotter Pins. Remove the pin that connects the Link to the
Lever and the pin that connects the Lift to the Lever.
5) Loosen the Jam Nut and remove the Lift from the Stem, then remove the Jam Nut from the
Stem.
6) Loosen the Lock Nut from the Bonnet and remove the nut and the Swivel Yoke.
Lever
Lift
Cotter Pins
Upp
er Pins
Link
Loosen this Jam Nut
Loosen this Lock Nut
Lift
Stem
Lock Nut
Swivel Yoke
Bonnet