EasyManua.ls Logo

Bellucci BISTRO - Troubleshooting and Handling

Bellucci BISTRO
38 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8 Troubleshooting and Handling
ERROR SOLUTIONS
Water tank
is empty
1. The water in the tank is already below the detection level; The
water tank is not installed correctly and too far from the sensor;
Water level sensor is broken;
2. Take out the tank and add water, make sure the water is not
higher than the “Max” line marked on the tank; Check and
reinstall the water tank; Replace a new sensor.
Grounds container
is full
1. The grounds count in the grounds container reached 15 pieces or
is already full;
2. Pull out the drip tray, take out the grounds container, and empty
the container.
Bean hopper
is empty
1. Coee bean hopper is empty or beans are stuck together;
2. Fill coee beans to the bean box; Stir the beans in the hopper
until they are loose.
Drip tray is not in
place
1. Not well fixed;Sensor broken; Magnet loose or broken;
2. Replace the drip tray; Replace new sensor; Replace new magnet.
Drip tray is full
1. The waste water in the tray is full; Sensor is dirty;
2. Pull out and empty the tray; Check and clean up the sensor.
Coee thermo-block
overheated
1. Temperature is over 160°C;
2. Wait for the tip in the screen to say “The hot water thermo-block
is cooling down, please wait..” While the thermo-block is cooling
down, no beverage can be made.
Steam thermo-block
heating over time
1. Temperature is over 160°C;
2. While the steam thermo-block is cooling down, no beverage can
be made.
Diverted valve
checking
1. The valve is in the wrong position after multiple self-tests;
2. Tap “checking” to do self-checking; Switch o, 5 seconds later
reboot the machine.
Environment tem-
perature is too low
1. The temperature of the environment is O°C or lower;
2. Please power on the machine when the temperature of
environment is 10°C - 40°C.
Lack of water
1. The inlet of tank water is blocked. The tank is unfixed; The
strainer of Brewer is blocked; The Flowmeter is damaged;
2. Check the way of water supply and tap “Fill Water”; Check the
tank outlet and reinstall it in place. Clean the strainer, reinstall
and push the tank to the end. Clean the strainer by Brewer Deep
Clean with tablets or by dissembling. Replace a new Flowmeter.
Switch o and restart the machine;
32