10.3 Heating/hot water output settings
RD532i N.G.
10.4 Heating/hot water output settings
RD532i L.P.G
10.5 Heating/hot water output settings
RD537i N.G.
10.6 Heating/hot water output settings
RD537i L.P.G
Natural gas G20
Display
code
Heat
output,
kW
Heat
input,
kW
Gas vol. flow rate
(l/min at
t
V
/t
R
= 80/60°C)
30 9.1 9.2 16.0
40 12.1 12.2 21.4
50 15.1 15.3 26.7
60 18.1 18.3 32.0
70 21.1 21.4 37.4
80 24.2 24.4 42.7
90 27.2 27.5 48.0
100 30.2 30.5 53.4
Table 20
Propane
Display
code
Heat output kW Heat input kW
40 12.1 12.2
50 15.1 15.3
60 18.1 18.3
70 21.1 21.4
80 24.2 24.4
90 27.2 27.5
100 30.2 30.5
Table 21
Natural gas G20
Display
code
Heat
output,
kW
Heat
input,
kW
Gas vol. flow rate
(l/min at t
V
/t
R
=
80/60°C)
30 11.1 11.3 19.7
40 14.9 15.0 26.3
50 18.6 18.8 32.8
60 22.3 22.5 39.4
70 26.0 26.3 45.9
80 29.7 30.0 52.5
90 33.4 33.8 59.1
100 37.1 37.5 65.6
Table 22
Propane
Display
code
Heat output, kW Heat input, kW
40 14.9 15.0
50 18.6 18.8
60 22.3 22.5
70 26.0 26.3
80 29.7 30.0
90 33.4 33.8
100 37.1 37.5
Table 23