11
LED DIAGNOSTICS
The red LED indicates the activation of inputs according to the legend hereunder:
STOP on with fixed light
DAS/PHOT rapid flashing
SWO 1 flash with 2-second interval
SWC 2 flashes with 2-second interval
OPEN+CLOSE 3 flashes with 2-second interval
By flashing slowly, the red LED also indicates that the unit is powered.
The green LED indicates the movement direction of the motor and the status of the gate according
to the legend hereunder:
OPENING 1 flash with 1-second interval
CLOSING 2 flashes with 1-second interval
Open gate without TCA on with fixed light