18
DIAGNOSTICS
One segment of the display is linked to each input. In the event of failure it switches on
according to the following scheme.
N.C. inputs are represented by the vertical segments. N.O. inputs are represented by the
horizontal segments.
SWC
STOP
SWO
PHOT
DAS
P.P. OPEN CLOSE
ERROR MESSAGES
The control unit checks the correct operation of the safety devices. In the event of failure, the following messages may be displayed:
ERR Error, self-learning stroke:
- activation of any input by the user
- door leaf i the closing limit switch
- HTR:ON logics
- memorisation of remote controls
ERR1 Check of management circuit integrity has failed
ERR2 Error, PHOTO TEST
ERR3 Encoder is broken.
WASTE DISPOSAL
If the product must be dismantled, it must be disposed according to regulations in force regarding the differentiated waste disposal
and the recycling of components (metals, plastics, electric cables, etc..). For this operation it is advisable to call your installer or a
specialised company.
Intelligent Security & Fire Ltd.