14
The logic menu allows you to activate or deactivate a function, in the same way as setting a dip-switch.
Other special functions follow the parameters and logic menus and may vary depending on the type of control unit or the software 
release.
USE OF PROGRAMMING KEYS
Press <PG> key to gain access to the Main Menu. These keys can be selected by pressing # and $ keys.
t*G#> is pressed, the Function Menu can be scrolled from top to bottom. 
t*G$> is pressed, the Function Menu can be scrolled from bottom to top.
t*G1(LFZJTQSFTTFEQSFTFUUJOHUPCFNPEJmFEDBOCFFOUFSFE
t5IFQSFTFUWBMVFTDBOCFNPEJmFECZVTJOH#> and <$> keys. 
t5IFWBMVFJTQSPHSBNNFEJG1(LFZJTQSFTTFEBHBJO5IFXPSEi13(wBQQFBSTPOUIFEJTQMBZ
See paragraph   “Programming Example”.
NOTES:
Simultaneously pressing <#> and <$> from inside a function menu allows you to return to the previous menu without making any 
changes. 
If the push-button  <$> is pressed with display off, this is like giving a step-by-step control.
When the board is switched on, the software version is displayed for around 5 sec  
Hold down the <#> key or the <$> key to accelerate the increase/decrease of the values.
After waiting 60s  the control unit quits programming mode and switches off the display.
PARAMETERS, LOGICS AND SPECIAL FUNCTIONS
In the tables hereunder the single functions available in the control unit are shown.
PARAMETERS (PAR)
MENU FUNCTION
MIN-MAX-(Default)
MEMO
TCA
Automatic closure time. It is activated only with  “TCA”=ON logic.
At the end of the preset time, the control unit controls a  closure operation.
1-240-(40s)
TM
Motor operating time. The total stroke time in the motor opening and closing phases 
is adjusted. 
With the ENC:ON logics, this value is automatically preset by the parameter self-
adjustment procedure (AUTO).
2-180-(60s)
Tsm
The space covered by the dooe leaf during braking in the closing phase is adjusted. 
Braking in the opening phase is automatically preset at 1/4 of the closing space.
0 = braking is disabled. 
With ENC:OFF logics the value is expressed in seconds. Braking after the triggering of 
the limit switch is adjusted.
0-99-(10%)
PMo
The torque applied to the motor in the opening phase is adjusted.* 1-99-(40%)
PMC
The torque applied to the motor in the closing phase is adjusted *. 1-99-(40%)
Pso
The torque applied to the motor during braking in the closing phase is adjusted.* 1-99-(40%)
Psc
The torque applied to the motor during braking in the opening phase is adjusted * 1-99-(40%)
TLS
The activation time of the service light is adjusted.
With parameter :0, the area light function is activated. The light is switched on when 
the motor is moving and during the TCA dwell time. The light switches off when the 
motor stops.
0-240-(60s)
SEAV
The triggering threshold of the anti-crash device (Encoder) during the normal speed 
phase.*
99: maximum sensitivity - 0: minimum sensitivity 
0-99-(0%)
SEAR
The triggering threshold of the anti-crash device (Encoder) during braking.*
99: maximum sensitivity - 0: minimum sensitivity
0-99-(0%)
AUX
The operating mode of the auxiliary output to terminals 19/20 is preset. See wire con-
nections in figure 2.
0: output configurated as SCA (open gate indicator light): Off with closed door, on 
with open door, slow flash during opening, rapid flash during closing.
1: output configurated as radio channel II integrated receiver.
2: output configurated as PHOT TEST (photocell test).
3: output configurated as flashing light.
4: output configurated as service light additional to the light on the geared motor. Its 
activation time is adjusted by TLS parameter.
0-4-(0)
* WARNING: 
An incorrect setting of these parameters may cause danger. 
Please comply with regulations in force!