EasyManua.ls Logo

Beninca CP.ZED230-E - Logic Functions

Beninca CP.ZED230-E
11 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15
LOGIC (LOG)
MENU FUNCTION
ON-OFF-
(Default)
MEMO
TCA
The automatic closure is enabled or disabled
On: enabled automatic closure
Off: disabled automatic closure
(OFF)
IbL
The multi-flat function is enabled or disabled.
On: enabled multi-flat function. The P.P. (Step-by-step) impulse or the impulse of the tran-
smitter have no effect in the opening phase.
Off: disabled multi-flat function.
(OFF)
PP
The operating mode of “P.P. Push button” and of the transmitter are selected.
On: Operation : OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
(OFF)
PRE
Forewarning flashing light enabled or disabled.
On: enabled forewarning flashing light. The flashing light is activated 3 s before the starting of
the motor.
Off: disabled forewarning flashing light.
(OFF)
blc
The lock function in the closing phase is enabled or disabled.
See paragraph “Operating mode with Enabled/Disabled encoder”.
On: Lock function is enabled.
Off: Lock function is disabled.
(ON)
ltca
During the TCA time, the blinker is enabled or disabled.
On: Activated blinker.
Off: De-activated blinker.
(OFF)
spn
The pick-up function with ENC:OFF logics is activated or deactivated.
On: the function is enabled. The first two seconds of operation are carried out at maximum
torque.
With ENC:ON logics, pick-up is automatically adjusted by the control unit.
(OFF)
htr
The Operator function is enabled or disabled.
On: Operator function enabled.
During operation, the OPEN/CLOSE push-buttons must be kept pressed.
Off: Automatic/semiautomatic operation.
(OFF)
IBCA
During the TCA phase, the PP and PED controls are enabled or disabled.
On: PP and PED controls are disabled.
Off: PP and PED controls are enabled.
(OFF)
ENC
The Encoder is enabled or disabled.
On: Enabled encoder.
Off: Disabled encoder (to be used with ZED series motors that are not equipped with built-in
Encoder).
NB: The Encoder can be possibly reset (from OFF to ON). A new self-calibration procedure is
required (AUTO menu).
(ON)
CVAR
The code programmable transmitters is enabled or disabled.
On: Radio receiver enabled only for rolling-code transmitters.
Off: Receiver enabled for rolling-code and programmable code transmitters (self-learning and
Dip Switch).
(OFF)
PHTo
The operating mode of the PHOT input is selected.
On: PHOT input is activated in both opening and closing.
In the opening phase: when the contact is opened, the motor stops. When the photocell is
released, the motor restarts with an opening movement.
In the closing phase: when the contact is opened, the motor stops. When the photocell is
released, the motor inverts its movement direction (opens).
Off: PHOT input is activated only in the closing phase.
In the closing phase: when the contact is opened, the motor stops and the movement direc-
tion is immediately reversed (opens).
(OFF)
rem
The remote storage of the radio transmitter codes is enabled or disabled (see par. REMOTE
LEARNING).
On: Enabled remote storage
Off: Disabled remote storage.
(OFF)