Faut
The check function of single failure is enabled or disabled.
Off: Single failure check is disabled.
On: Single failure check enabled in compliance with the Machinery Directive 98/37/CE.
(OFF)
AMP
The anti-crash amperometric sensor is disabled or enabled. Its sensitivity is adjusted
by parameters SNSO and SNSC.
On: Amperometric sensor activated.
Off: Amperometric sensor deactivated.
(OFF)
2pha
Lack of phase check in case of three-phase power supply is enabled or disabled.
On: Check activated.
Off: Check deactivated.
(OFF)
inva
The movement reversion in the event of triggering of the amperometric sensor or the
DAS input is activated or deactivared.
On: Reversion activated. The activation of the edge or the sensor causes a movement
reversion (opening) for approx. 3 sec.
Off: Movement reversion not activated. The activation of the edge or the sensor causes
the immediate stopping of the gate movement.
(OFF)
Smot
The motor protection switch is enabled or disabled. Its sensitivity is adjusted by SAFM
parameter.
On: amperometric sensor activated.
Off: amperometric sensor deactivated.
(OFF)
doSp
The rapid movement reversion is enabled or disabled after the activation of the photo-
cell in the closing phase.
ON: Rapid reversion activated. The movement reversion time, in the event of activation
of the photocell, is reduced to approx. 1 sec.
To be used only on light-weight and fast doors.
OFF: Rapid reversion deactivated. The movement reversion time, in the event of activa-
tion of the photocell, is approx. 3 sec.
(OFF)
disg
Auxiliary capacitor
On: 230Vac motor - single-phase and Auxiliary capacitor (terminal 7/8)
Off: 400Vac motor - Three-phase .
(OFF)
NUMBER OF CYCLES (Nman)
The number of cycles (open+close) completed by the system is displayed.
When the push-button <PG> is pressed once, the first 4 digits are displayed, if the push-button is pressed once more, the last 4
digits are displayed.
E.g. <PG> 0012 >>> <PG> 3456: 123.456 cycles were performed.
RESET (RES)
RESET of the control unit. WARNING: Returns the control unit to the default values.
When the <PG> push-button is pressed once, the RES wording begins to flash, if the push-button<PG> is pressed once more,
the control unit is reset.
Note: neither the transmitter codes nor the position and stroked of the gate leaf will be erased from the receiver.

Other manuals for Beninca THINK

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Beninca THINK and is the answer not in the manual?

Beninca THINK Specifications

General IconGeneral
BrandBeninca
ModelTHINK
CategoryControl Unit
LanguageEnglish

Related product manuals