57
Interface Settings
RS-232 protocol
Baud Rate 115200 bps (default)
Changeable settings in User OSD
(9600/19200/38400/57600/115200)
Data Length 8 bit
Parity Check None
Stop Bit 1 bit
Flow Control None
Software specification
1. When input cmd fail, e.g. correct input is “*pow=?#” but input “*po=?#”, or input “*mute=on#”
while projector is already mute, it will show “*Illegal format#”.
2. When input cmd but projector has no such function item, e.g. input “*sour=RGB2#” but
projector has no RGB2 connector, it will show “*Unsupported item#”.
3. When cmd and function are both workable, but it’s not under the status which cmd can be
executed, e.g. input “*asp=4:3#” while not connecting source, it will show “*Block item#”.
4. When input “query” cmd (with “?”), e.g. input “*sour=?#”, it will echo the same input strings
with some value.
5. Press “Enter” key after” ”, it should be no echo and skip to the next row.
6. Press “Space” and “Enter” key after” ”, it will echo”*Illegal format#”
Command Category
Refer to Appendix 2

Other manuals for BenQ MX613ST