Ceramic Body and Cutting tip
Notes: pay attention to preventing electric shock and ensuring in-place installation while
installing ceramic body. The incorrect installation is prohibited.
2. Check whether cutting torch and ceramic body are damaged every 24 hours, and timely
replace if they are damaged and cannot operate normally;
3. Clean surface of the laser head every 24 hours;
4. Check protective lens for its operation conditions every 72 hours, use dedicated cleaning tools
to clean if there are somewhat dirt and welding slag, and timely replace if it influences cutting
effect;