19 / 49
Light emitting test
After normal power up, press the laser power switch on the right side cover, and then set the
light emitting energy and time directly on the control panel, and test if the laser emitting function
is normal. If there is no laser emitting from the spot spray laser tube, it means that there are
problems with the laser emitting, and check is required. In case of laser emitting found from the
laser tube, but no laser emitting from the cutting head, it means improper position of the light
route, and adjustment of light route is needed.
If there is no laser emitting, first check the setting of laser parameters. Improper laser
parameters may cause equipment malfunction or laser power cannot be adjusted. If the laser
parameters are determined correct and there is no emitting still, you need to check the hardware
problem.
The control panel of some types of machines is equipped with ammeter. With
the ammeter, you can check if the power is normal.
Light route adjustment
As the center of the laser head is fixed, the nozzle center can be changed through adjustment
screws on the cutting head to make it correspond to the laser center. Paste a layer of tape on the
nozzle, then emit laser, and check if the hole punched on the tape by the laser coincides with the
nozzle center; adjust the 4-faced screws repeatedly until the laser center coincides with the nozzle
center.