33 / 49
6. Add No. 0 lithium-based lubricating grease to the lubrication hole on the vertical bearing
seat of hydraulic lifting platform.
7.6 Annual maintenance requirements:
1. Check and replace filter element of refrigeration dryer.
2. Replace filter element at air inlet of air compressor, and replace oil filter (smaller) in air
compressor in severe environment.
3. Check and replace air filter element in the gas circuit cabinet of the machine.
4. Replace deionized water for cooling and circulating in the laser.
7.7 Requirements for maintenance every 4,000 hours
1. Check oil level in forwarding and backwarding reducer on workbench, check oil level in
lifting reducer, and replace gear case oil of forwarding and backwarding reducer and
lifting reducer if necessary.
2. Replace air compressor oil.
3. Replace oil-gas separator of air compressor (larger).
Service Schedule of Laser Cutting Machine for Optical Fiber