3.2.5 Resistance
> Open Circuit Voltage: 200M range: 3V
Other ranges: less than 700mV
> Overload Protection: 250V DC or rms AC
NOTE: On 200M range, if short input, display will read 1M.
This 1M should be subtracted from measurement results.
Range Resolution Accuracy
200 0.1 ±(1.0% of rdg +10 digits)
2K 1 ±(1.0% of rdg +1 digit)
20K 10 ±(1.0% of rdg +1 digit)
200K 100 ±(1.0% of rdg +1 digit)
2M 1K ±(1.0% of rdg +1 digit)
20M 10K ±(1.0% of rdg +5 digits)
200M 100K ±(5.0% of (rdg - 10 digits) +20 digits)
MultimetroDigitale.book Page 13 Friday, September 26, 2003 6:34 PM