2
Medium fan speed
3
High fan speed
SL
In NIGHT mode all displays on the control panel
1
go out, except for the NIGHT indi-
cator
16
. In NIGHT mode, the low fan speed is always active.
A
In AUTO mode, the fan speed is automatically adjusted depending on how close the
current humidity is to the desired target humidity.
7.4 Timer function
The air humidifier features a timer function that you can use to determine the number of hours the air
humidifier should run for before it automatically switches itself o. You can set a timer for between 1 and
9 hours.
1. Use the timer button
14
to select your desired timer. The currently set timer lights up on the display
1
(e. g. 5 h). After a few seconds, the current air humidity is shown again on the display
11
.
2. To switch o the timer, press the timer button
14
repeatedly until 0h is shown in the display. The timer
is now switched o.
8. CLEANING AND MAINTENANCE
8.1 Filter drying function
Mould and bacteria can form in the filter
4
when the air humidifier is not in use. Therefore, always empty
the residual water from the tank and dry all parts when the device is not in use. Allow the filter
4
to air dry
or use the filter drying function for faster drying:
1.
Before activating the filter drying function, ensure that the residual water has been emptied from the
tank (residual moisture may collect under the filter holder
7
, which must be dried manually). The filter
drying function can only be started once the residual water has been emptied.
2. To activate the filter drying function, press and hold the fan speed button
15
for 5 seconds. The filter
drying indicator
18
will start to light up. The filter drying function now dries the filter
4
at the highest
setting for the next 3 hours. To switch o the filter drying function prematurely, press any other button.
3. After the time has elapsed, check that the filter
4
is completely dry. If the filter
4
is not completely dry,
activate the filter drying function again.
8.2 Cleaning the filter
WARNING
Before cleaning, always ensure that the mains plug of the air humidifier has been properly
disconnected. Only clean the filter
4
according to the method described in these instruc-
tions for use. Never clean the filter
4
in a washing machine or dishwasher.
Regular cleaning of the filter
4
is required to ensure hygienic and fault-free operation. Rinse the filter
4
weekly under running water to remove dust, dirt and hair.
NOTICE
Replace the filter
4
after 6 months at the latest (see section “8.3 Changing the filter”). If the filter
4
is
calcified, descale it as described in section “8.6 Descaling”.