47 Conference Control Commands
4.8 ~p commands
MU ping and Warning Time Speaking (WTS)
These commands can be used to ping the microphone LED or the mic button. The so-
called warning time speaking (WTS) can be activated, which is a signal that can be sent
to the MUs to signal that the speaking time is advanced and is about to end, or is to be
ended by the chairman unless it is terminated independently. The signal is a flashing of
the microphone LED and the mic button - just like the simple ping.
Communication direction
Controller -> CU -> MU
Syntax
Description
~p muad
Pinging the microphone LED
~p muad m
Activate/Deactivate Warning Time Speaking
(WTS)
Parameters
Description
muad
MU ID
[range: 0x1 0xFFFFFF]
m
0 = Stop WTS signaling
1 = WTS signaling simple delegate or double
delegate (left button)
2 = WTS signaling double delegate
(right button)
3 = WTS signaling double delegate (left & right)
Example
MU Ping and Starting/Stopping WTS
Transmit:
~p 281<CR>
This command pings the MU with muad 0x281.
Receive:
<CR><LF>
>
Transmit:
~p 281 1<CR>
This command starts WTS on MU with muad 0x281.
Receive:
<CR><LF>
>
Transmit:
~p 281 0<CR>
This command stops WTS on MU with muad 0x281.
Receive:
<CR><LF>
>