48 (Advanced) MU List Management
5 (Advanced) MU List Management
This chapter deals with all necessary commands for handling the CU-internal MU list. If
you want to manage the voting functions of the MUs without further help from the
Quinta software, you have to read and manage this list. The Quinta CU-internal MU list
is a fixed list of 150 positions (range of list positions: 0x00 - 0x95). Only the complete
reading of all 150 list positions can guarantee that all MUs have been recorded. Empty
list positions or a listing of unregistered MUs are possible and are only recorded in this
way. The list is written by either CU or PC based on detecting the first empty position
(requiring sequential parsing).
5.1 T 0 and SList[] commands
MU List: positions and various information
This command group queries the CU-internal MU list and returns various information
about the list parameters.
Get list position information
Position in MU list (CU-internal)
[150 positions in range: 0x00 0x95]
>> CU-REPLY message on T 0 pp 0 command <<
Microphone unit status messages for list
positions
Position in MU list (CU-internal)
[150 positions in range: 0x00 0x95]
Source MU ID
[range: 0x000001 0xFFFFFF]