7 Connectivity and Information Commands
2 Connectivity and Information Commands
All commands in this chapter are applicable in Conference Mode as well as
Microphone Mode.
2.1 U commands
Login to communication port
Note
The U commands are only sent by the controller to the CU and are not passed on to
other integrated units.
As already stated, in the further course of this document, the direction of
communication is presented in short form as in the first line of the following table.
Communication with the Quinta Control Unit via RS232, USB or Ethernet requires the
external controller to login first. Although the Quinta Control Unit offers three possible
physical ports namely: RS232, USB, Ethernet only one port can be used at a time. Thus
only one external controller can communicate with the Quinta Control Unit at the same
time.
Communication direction
Syntax
U 0
U 0 pwd
U 1 pwd
U 1
U B
Parameters
pwd