Transport, installation and connection
4-7
technology for your future
Automation
BFI
Type
Ser.-No.:
24Vdc
Germany
1
2
3 4 5
6
7
By using a ball-flange (optional, part No. 6590-9020-
01), the adjustment can be carried out easily ensur-
ing that the ideal sighting point is set mechanically.
Connection of the fibre optic cable by using the swi-
vel nuts at both ends. If temperature of over 100
degrees Celsius occur at the flame scanner despite
the inflow of cooling air caused by the heat dissipa-
tion of the sighting tube, heating insulator (optional,
part No. B 512.1) has to be used. In case of pres-
surised combustion, an additional 3-way-ball-valve
(optional, part No. B 520) has to be fitted for protec-
tion. The exit of hot gas after removal of the SKL-
probe is prevented, ensuring further cooling and
purging of the arrangement.
The entire mechanical peripheral system can be
supplied by BFI Automation.
1 Flame scanner
2 Fibre optic cable
3 SKL-probe
4 Heating insulator
5 3-way-ball-valve
6 Double nipple
7 Ball-flange