OPERATION OF THE BGates LT TERMINALS (Fig. 1)
A) Terminal board M1
220V power supply
B) Terminal board M2
Automation open control relay. Relay contacts:
- NO normally open
- NC normally closed
- C common
C) SW1 button - Reset to factory settings
Turn on the module, wait for the three LEDs to light up at the
same time and then press the C button (SW1) within 5 seconds.
Acceptance of the command will be conrmed by the rapid
ashing of the right LED (looking at the label and reading BGates).
CAUTION:
This process deletes all registered telephone numbers and restores
messages and settings to the initial values (including passwords to
0000).
D) SIM Card insertion seat
The SIM inserted must be congured without the PIN number. The
device will not work if a SIM congured with the PIN request is
inserted.
The connections to the control relay must be provided in function
of the type of apparatus that must be automated. The simplest
approach is to identify the button/key to open the device to
automate and make a parallel connection. If the plant is not tted
with any, refer to the manual of the plant to be automated to
determine the correct connection with the control unit in order to
automate the opening.
Once powered, BGates LT will proceed with registration on the
GSM network. Registration may last a few minutes.
The system is ready for use after this operation.