- 8 -
USE
DESCRIPTION OF UNIT
Max. air mass flow rate
G20 kg/s 0.0215 0.0224
Min. air mass flow rate
G20 kg/s 0.0047 0.0048
CO2 content (Nominal heat input)
G20 % 5.16 5.16
O2 content (Nominal heat input)
G20 % 11.7 11.7
CO content (Nominal heat input)
G20 ppm 227 229
NOx class
6
Weighted NOx
ppm 17.98 30.53
Max. flow rate (rise 25 °c)
kg/min 14.0 16.0
Max. water pressure (Pw) bar 10 10
Min. water pressure (Pw) bar 0.2 0.2
Electrical power supply
230 V ~ 50 Hz
Degree of electrical protection
IPX4 IPX4
Ignition method
Water control automatic pules ignition
Destination country
GB - IE
Gas inlet joint
G 1/2 G 1/2
Cold water inlet joint
G 1/2 G 1/2
Hot water outlet joint
G 1/2 G 1/2
Flue duct diameter
mm Ø 60 x Ø 100 Ø 60 x Ø 100
ErP Data MULTIPOINT 14S MULTIPOINT 16S
Declare load profile XL XL
Water heating energy efficiency (η
WH
) % 84.0 80.5
Water heating energy efficiency class A A
Daily gas consumption (corrected) kWh 23.583 24.845
Daily electrical consumption (corrected) kWh 0.064 0.064
Annual fuel consumption AFC (GJ) 18 19
Annual electricity consumption AEC (kWh) 14 14
NOx
mg/kWh 29 47
Indoor sound power level (L
WA
) dB 61 63
G20 Hi. 34,02 MJ/m
3
(15°C, 1013,25 mbar)
G30 Hi. 45,65 MJ/kg (15°C, 1013,25 mbar)
G31 Hi. 46,34 MJ/kg (15°C, 1013,25 mbar)
1 mbar corresponds to approx. 10 mm H
2
0