EasyManua.ls Logo

Binder 9010-0213 User Manual

Default Icon
61 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Issue 02/2015 Art. No. 7001-0070
Operating Manual
FED (E2)
Drying and heating ovens
with forced convection and enhanced timer
functions
with microprocessor temperature controller
Model Model version Art. No.
FED 53 (E2) FED053-230V 9010-0210, 9110-0210
FED 53-UL (E2) FED053UL-120V 9010-0211, 9110-0211
FED 115 (E2) FED115-230V 9010-0212, 9110-0212
FED 115-UL (E2) FED115UL-120V 9010-0213, 9110-0213
FED 240 (E2) FED240-230V 9010-0214, 9110-0214
FED 240-UL (E2) FED240UL-208V 9010-0215, 9110-0215
FED 400 (E2) FED400-400V 9010-0216, 9110-0216
FED 400-UL (E2) FED400UL-208V 9010-0217, 9110-0217
FED 720 (E2) FED720-400V 9010-0218, 9110-0218
FED 720-UL (E2) FED720UL-208V 9010-0219, 9110-0219
BINDER GmbH
Address Post office box 102
D-78502 Tuttlingen
Tel. +49 7462 2005 0
Fax +49 7462 2005 100
Internet http://www.binder-world.com
E-mail info@binder-world.com
Service Hotline +49 7462 2005 555
Service Fax +49 7462 2005 93 555
Service E-Mail service@binder-world.com
Service Hotline USA +1 866 885 9794 or +1 631 224 4340 x3
Service Hotline Asia Pacific +852 390 705 04 or +852 390 705 03
Service Hotline Russia and CIS +7 495 98815 16

Table of Contents

Questions and Answers:

Binder 9010-0213 Specifications

General IconGeneral
BrandBinder
Model9010-0213
CategoryOven
LanguageEnglish

Summary

SAFETY

COMPLETENESS OF DELIVERY, TRANSPORTATION, STORAGE, AND INSTALLATION

INSTALLATION

Electrical connection

Power supply requirements, plugs, protective conductors, and circuit breaker recommendations.

START UP

Turning on the chamber

Step-by-step guide for powering on and initiating the chamber.

CONTROLLER SETTING

Display / entry of temperature and ventilation set-points (without ramp function)

Setting temperature and fan speed without temperature ramps.

Time functions: Continuous operation and Timer operation

Explanation of continuous and timer operation modes.

Switching between Continuous operation and Timer operation

Guide on switching between continuous and timer modes.

Continuous operation

Detailed steps to activate and use continuous operation mode.

Setting the timer values

Instructions on setting timer values for operation.

User level settings

TEMPERATURE SAFETY DEVICES

Temperature safety device class 2 (DIN 12880)

Explanation of Class 2 safety device, its function, and checking.

Temperature safety device class 3.1 (DIN 12880) (option)

Explanation of optional Class 3.1 safety device, its function, and adjustment.

MAINTENANCE, CLEANING, AND SERVICE

Maintenance intervals, service

Guidelines on maintenance frequency and service requirements.

Cleaning and decontamination

Procedures for cleaning and decontaminating the chamber.

Cleaning

Steps and recommended agents for cleaning interior/exterior surfaces.

TROUBLESHOOTING

Temperature

Common temperature faults, causes, and required measures.

Controller

Common controller faults, causes, and required measures.

FED technical data

Related product manuals