EasyManua.ls Logo

Binder FED 53 - User Manual

Binder FED 53
61 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Issue 02/2015 Art. No. 7001-0070
Operating Manual
FED (E2)
Drying and heating ovens
with forced convection and enhanced timer
functions
with microprocessor temperature controller
Model Model version Art. No.
FED 53 (E2) FED053-230V 9010-0210, 9110-0210
FED 53-UL (E2) FED053UL-120V 9010-0211, 9110-0211
FED 115 (E2) FED115-230V 9010-0212, 9110-0212
FED 115-UL (E2) FED115UL-120V 9010-0213, 9110-0213
FED 240 (E2) FED240-230V 9010-0214, 9110-0214
FED 240-UL (E2) FED240UL-208V 9010-0215, 9110-0215
FED 400 (E2) FED400-400V 9010-0216, 9110-0216
FED 400-UL (E2) FED400UL-208V 9010-0217, 9110-0217
FED 720 (E2) FED720-400V 9010-0218, 9110-0218
FED 720-UL (E2) FED720UL-208V 9010-0219, 9110-0219
BINDER GmbH
Address Post office box 102
D-78502 Tuttlingen
Tel. +49 7462 2005 0
Fax +49 7462 2005 100
Internet http://www.binder-world.com
E-mail info@binder-world.com
Service Hotline +49 7462 2005 555
Service Fax +49 7462 2005 93 555
Service E-Mail service@binder-world.com
Service Hotline USA +1 866 885 9794 or +1 631 224 4340 x3
Service Hotline Asia Pacific +852 390 705 04 or +852 390 705 03
Service Hotline Russia and CIS +7 495 98815 16

Table of Contents

Questions and Answers

  • M
    Monique KlineAug 17, 2025
    What to do if my Binder Oven chamber has no function at all?
    • M
      Michelle JacobsonAug 17, 2025
      If your Binder Oven chamber has no function, first check the connection to the power supply. If the connection is fine, check the chamber fuse and replace it if necessary. If the fuse responds again, contact Binder service.
  • K
    Kristi CollinsAug 20, 2025
    What to do if my Binder FED 53 Oven set-point temperature is not reached after the specified time?
    • A
      Alejandro WilliamsAug 20, 2025
      If the set-point temperature in your Binder Oven isn't reached after the specified time, make sure the chamber door is completely closed. Also, inspect the door gasket and replace it if defective. Calibrate and adjust the controller and check the power supply to ensure it matches the required voltage (115V or 230V).
  • J
    Jessica WilsonAug 22, 2025
    Why does my Binder FED 53 Oven chamber not heat up, and the red heating control light in the display is not lit?
    • V
      Vincent MendezAug 23, 2025
      If your Binder Oven chamber isn’t heating up and the red heating control light is off while the controller display is working, the timer may have run off. Program the timer or switch to continuous operation. If this doesn't solve the problem, contact Binder service.
  • R
    reidrobertAug 26, 2025
    What to do if my Binder FED 53 Oven chamber is heating permanently and the set-point is not held?
    • S
      Sarah WalshAug 26, 2025
      If your Binder Oven chamber is heating permanently and not maintaining the set-point, calibrate and adjust the controller. For other potential causes, contact Binder service.
  • C
    christopherleonAug 28, 2025
    What to do if my Binder Oven chamber doesn’t heat up, and the red heating control light in the display is lit?
    • M
      Monique ContrerasAug 28, 2025
      If your Binder Oven chamber isn’t heating up but the red heating control light is lit, contact Binder service.
  • H
    Heather Fox MDAug 31, 2025
    Why is the red alarm light lit on my Binder FED 53 Oven?
    • T
      Tanya WilsonAug 31, 2025
      If the red alarm pilot lamp of the safety device is lit on your Binder Oven, the safety device class 2 has likely turned off the chamber. Allow the chamber to cool down, then press the RESET button. Check the temperature set-point and the safety device class 2 settings, and select a suitable limit value if needed. For other potential causes, contact Binder service.
  • R
    Robin WestSep 2, 2025
    How to fix temperature being too high in the Binder FED 53 chamber?
    • E
      Elizabeth GarrisonSep 2, 2025
      If the temperature inside your Binder Oven chamber is too high and the red alarm pilot lamp of the safety device is lit, it indicates that safety device class 3.1 has responded. Check the temperature set-point and the settings of safety device class 3.1.
  • H
    Harold ColeSep 5, 2025
    Why is my Binder FED 53 chamber without function, with only the green stand-by LED lit?
    • T
      Thomas LewisSep 5, 2025
      If your Binder Oven chamber has no function and only the green “stand-by” LED is lit, the chamber is likely in stand-by mode. Press the ON/OFF button until the display lights up.
  • V
    Victoria ThompsonSep 8, 2025
    Why does the fan in my Binder FED 53 not turn or turns too slowly?
    • W
      William JohnstonSep 8, 2025
      If the fan in your Binder Oven doesn’t turn or turns too slowly, first check if the fan speed is set too low and set the fan speed to 100%. If the problem persists, contact Binder service.
  • K
    Kathy HaleSep 12, 2025
    Why are there deviations from the indicated heating-up times in my Binder FED 53?
    • N
      Nicholas ToddSep 12, 2025
      Deviations from the indicated heating-up times in your Binder Oven can occur if the chamber is fully loaded. Reduce the load or allow longer heating-up times.

Summary

Safety Instructions

Legal Considerations

Information on legal aspects and user responsibilities for manual content.

Structure of Safety Instructions

Explains the organization and components of safety information.

Signal Word Panel

Details on signal words used to indicate danger severity.

Safety Alert Symbol

Explanation of the safety alert symbol and its meaning.

Pictograms

Visual representations of hazards and mandatory actions.

Word Message Panel Structure

Defines the format and content of hazard warning panels.

Safety Label Locations

Identifies the positions of safety labels on the chamber.

Type Plate Information

Details found on the chamber's identification plate.

General Safety for Installation and Operation

Essential safety guidelines for installing and operating chambers.

Intended Use

Specifies the authorized applications and limitations of the chamber.

Chamber Description

Equipment Overview

Visual guide to the chamber's components and controls.

Delivery, Transportation, Storage, and Installation

Unpacking and Checking Delivery

Procedure for inspecting the chamber upon receipt.

Safe Lifting and Transportation

Guidelines for safely moving and transporting the chamber.

Storage Guidelines

Recommendations for storing the chamber before installation.

Installation Location and Ambient Conditions

Requirements for the chamber's installation site and environment.

Installation Procedures

Electrical Connection

Instructions for connecting the chamber to the power supply.

Suction Plant Connection

Guidance on connecting an optional suction plant.

Startup and Operation

Turning On the Chamber

Step-by-step guide to powering on the chamber.

Heating Operation Display

Explanation of indicators for heating status.

Air Change Adjustment

How to adjust the air circulation within the chamber.

Controller Settings

Set-points Without Ramp Function

Setting temperature and fan speed without programmed ramps.

Set-points With Temperature Ramp

Setting temperature and fan speed with programmed ramps.

Time Functions: Continuous;Timer Operation

Configuration of continuous and timer-based operation modes.

User Level Settings

Accessing and modifying user-configurable controller parameters.

Temperature Programming Example

Illustrative example of setting up a temperature program.

General Notes on Controller

Miscellaneous notes and tips for controller usage.

Temperature Safety Devices

Class 2 Safety Device Operation

Functionality and checking of the Class 2 temperature safety device.

Class 3.1 Safety Device (Option)

Details on the optional Class 3.1 temperature safety device.

Audible Over-Temperature Alarm (Option)

Description of the optional audible alarm feature.

Optional Features and Accessories

Communication Software APT-COM

Information on using the chamber with APT-COM™ software.

Data Logger Kit

Details about the optional data logger for temperature recording.

HEPA Fresh Air Filter (Option)

Information on the optional HEPA filter for air purification.

Mostly Gas-Tight Version (Option)

Description of the gas-tight feature for specific models.

Inert Gas Connection (Option)

Instructions for connecting inert gas for specific models.

Analog Output for Temperature (Option)

Details on the analog output for temperature data transmission.

Maintenance, Cleaning, and Service

Maintenance Intervals and Service

Schedule and procedures for regular maintenance and service.

Cleaning Procedures

Guidelines for cleaning the chamber's interior and exterior.

Decontamination Procedures

Steps for decontaminating the chamber after hazardous substance contact.

Returning the Chamber to BINDER

Process for sending the chamber back to BINDER for service.

Disposal Guidelines

Transport Packing Disposal

Instructions for disposing of the chamber's packaging materials.

Decommissioning the Chamber

Procedure for safely taking the chamber out of service.

Disposal in Germany

Regulations for disposing of the chamber in Germany.

Disposal in EC Member States

Regulations for disposing of the chamber within EC countries.

Disposal in Non-EC States

Guidelines for disposal outside European Community states.

Troubleshooting Guide

Technical Specifications

Factory Calibration and Adjustment

Information on the chamber's factory calibration process.

Definition of Usable Volume

Explanation of how the chamber's usable volume is calculated.

Over Current Protection

Details on the chamber's protection against overcurrent.

FED Technical Data

Comprehensive technical data table for FED models.

Equipment and Options

Overview of standard equipment and available optional features.

Accessories and Spare Parts

List of available accessories and replacement parts.

Certifications and Compliance

EC Declaration of Conformity

Statement confirming compliance with EC directives.

GS Mark of Conformity Certificate

Certificate for the GS safety mark from VDE Institute.

Product Registration

Contamination Clearance Certificate

For Chambers Outside North America;Central America

Form for declaring contamination status for non-NA/CA chambers.

For Chambers in North America;Central America

Form for declaring contamination status for NA/CA chambers.

Binder FED 53 Specifications

General IconGeneral
BrandBinder
ModelFED 53
CategoryOven
LanguageEnglish

Related product manuals