EN
The outlet connection is not blocked or isolated by any valves.
Ensure all electrical and mechanical connections are correctly made.
Set the pump speed to the minimum frequency 20 Hz and start the pump to remove any air from the circuit.
Before starting:-
All required interlocks are tested and operational.
Suitable material for pumping is available at the suction hose.
Check the gearbox oil level, please note the the gearbox is supplied with life lubricant and does not need
any maintenance.
SYSTEM OPERATION
Inspect for any system leaks.
Set the pump cycle rate to achieve the required paint volume and then adjust the system back pressure regulator
to achieve the desired system fluid pressure.
Smart Mode:
The return line ‘back pressure’ regulator responds to the changes in system fluid flow demand, (due to variable
paint usa