S19 Pro Hydro Server Installation Guide
1. Overview
1.2 Specifications
S19 Pro Hydro
208-A
SHA256/BTC/BCH
, TH/s 154.5 ± 3% 162 ± 3% 169.5 ± 3%
ower on wall@Tj65°C, Watt
(1-1)
4558± 5% 4780± 5% 5000 ± 5%
ower efficiency on wall @Tj65°C, J/TH
(1-1)
29.5 ± 5% 29.5 ± 5% 29.5 ± 5%
Detailed Characteristics Value
Power Supply
Power supply AC input voltage, Volt
(2-1)
342~418
Power supply AC Input Frequency Range, Hz
47~63
Power supply AC Input current, Amp
(2-2)
30
Hardware Configuration
Network connection mode RJ45 Ethernet 10/100M
Server Size (Length*Width*Height, w/o
package), mm
410*196*209
Server Size (Length*Width*Height, with package),
mm
570*316*430
Net weight, kg
15.2
Gross weight, kg 17.5
Environment Requirements
Operation temperature, °C
(2-3)
0~40
Inlet water temperature, °C 20-40
Water flow L/min
8±10%
Water pressure bar
≤
Storage temperature, °C -20~70
Operation humidity(non-condensing), RH 10~90%