EasyManuals Logo

Bitronics M350 User Manual

Bitronics M350
82 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #65 background imageLoading...
Page #65 background image
ML0038 September 27, 2017 - 65 - Copyright 2017 Bitronics, LLC
7.0 ANALOG (TRANSDUCER) OUTPUT OPTION
7.1 Introduction
The Transducer Output options (0 -1 mA or 4-20 mA) feature 3 separate outputs each
with two terminals, one of which is common to all three outputs and one which
provides a unique return path for each output.
7.2 Specifications
Outputs: 3 bi-directional, 0-1mA (active) or 4-20mA (loop powered, passive)
0 – 1mA Current Range
Output Range: 0 to +/-1mA into 10K ohms or less; Overload to
+/-2.1mA into 5K ohms or less.
Resolution: 0.22uA
Output Resistance: 500 ohm
4 – 20mA Current Range
Output Range: 4 to 20mA
Resolution: 1.1uA
Max Loop Voltage: 40Vdc
Max Voltage Drop: 2.3V @ 20mA
4 – 20mA Internal Loop Supply
Max Output Voltage: 6V @ 60mA,
Accuracy 0.25% of Full Scale Input
Data Update Rate (poll rate): 100ms minimum
7.3 Connections
The connections for the 0-1mA output option are shown in figure 9, while the
connections for the 4-20 mA with external and internal loop are shown in figure 10.