101-B00 Page 7/16
MAINTENANCE:
Failure to disconnect and lockout
electrical power or engine drive
before attempting maintenance can
cause severe personal injury or death
Hazardous
machinery can
cause serious
personal injury.
Failure to disconnect and lockout
electrical power before attempting
maintenance can cause shock, burns
or death
Hazardous voltage.
Can shock, burn or
cause death.
Failure to relieve system pressure
prior to performing pump service or
maintenance can cause personal
injury or property damage.
Hazardous pressure
can cause personal
injury or property
damage
Disconnecting fluid or pressure
containment components during pump
operation can cause serious personal
injury, death or major property damage
Hazardous pressure
can cause personal
injury or property
damage
If pumping hazardous or toxic fluids,
system must be flushed and
decontaminated, inside and out, prior
to performing service or maintenance
Hazardous or toxic
fluids can cause
serious injury.
Operation without guards in place can
cause serious personal injury, major
property damage, or death.
Do not operate
without guard
in place
NOTICE:
Maintenance shall be performed by qualified technicians
only. Follow the appropriate procedures and warnings
as presented in this manual.
SCHEDULED MAINTENANCE
LUBRICATION
NOTICE:
To avoid possible entanglement in moving parts do not
lubricate pump bearings, gear reducer or any other parts
while the pump is running.
NOTICE:
The inboard bearings of GX models shipped without the
gear reducer attached are NOT greased at the factory.
The inboard bearing MUST be greased after installation
of the gear reducer and prior to initial pump start up.
NOTICE:
If pumps are repainted in the field, ensure that the
grease relief fittings (76A) are functioning properly after
painting. Do NOT paint them closed. Remove any
excess paint from the fittings.
Pump bearings should be lubricated every three months at
minimum. More frequent lubrication may be required,
depending on the application and operating conditions.
Recommended Grease:
Mobil® - Mobilgrease XHP222,
Exxon® - RONNEX MP Grease,
or equivalent Lithium grease..
Greasing Procedure:
1. Remove the grease relief fittings (76A) from the bearing
covers (27, 27A).
2. SLOWLY apply grease with a hand gun until grease
begins to escape from the grease relief fitting port. (76)
3. Replace the grease relief fittings (76A).
DO NOT overgrease pump bearings. While it is normal for
some grease to escape from the grease tell-tale hole after
lubrication, excessive grease on pumps equipped with
mechanical seals can cause seal failure.
If equipped with a Blackmer gear reducer, refer to the ‘Gear
Reducer Lubrication’ section of this manual.
STRAINERS
Strainers must be cleaned regularly to avoid pump starvation.
Schedule will depend upon the application and conditions.