What to do if I have a quick-disconnect yoke problem with my Blizzard B54 Snow Blower?
- Ssteven30Aug 10, 2025
If the quick-disconnect pin is dirty, clean and oil it, following the service instructions. If the quick-disconnect pin is defective due to forced engagement or incorrect handling, replace it. If the axial loads are too high, clean and grease the telescopic tubes, replacing them if necessary. If the shaft length is excessive, shorten it by cutting both telescopic tubes and the shield, and remove any burrs. Also, consider replacing the quick-disconnect pin.