MAINTENANCE
Daily maintanence
To clean Cleone
Do not use chemicals to clean the surface. Alcohol, petrol, organic and
inorganic acids, strong basic chemicals (such as concentrated dish
washing detergent) will cause damage to the surface.
Do not use hard or sharp tools to clean Cleone.
Action Step
1 Clean the outer surface with a soft moist cloth and a weak soap solution to remove dust, stains and dirt.
2 Dry with a soft dry cloth.
Regular maintenance
The water quality controls the maintenance frequency. If the feed water
contains high levels of suspended solids, more frequent maintenance can
be necessary.
Regular maintenance is important for correct function and long
term operation. Only educated and approved personnel can do the
maintenance.
For instructions on how to do maintenance, see Complete User manual on
www.bluewater.se
Frequency Description
6 months Replace the coarse sediment prefilter (CL-20)
Replace the fine sediment prefilter (CL-5)
Replace the activated carbon prefilter (CL-C)
Replace the integrated mineral filter
Use disinfectant to clean the system.
Flush the activated carbon prefilter
1 year Replace the activated carbon postfilter (CL-Inline-C)
Replace the UV lamp
Flush the activated carbon postfilter
Measure the air cushion pressure in the clean water tank.
3-5 years Replace the reverse osmosis membrane