EasyManuals Logo
Home>BLUM>Measuring Instruments>TC60

BLUM TC60 User Manual

BLUM TC60
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
System overview
10 by Blum-Novotest 2012
2.4 Technical data
TC60 TC61 TC63-30 / TC76-T
Approach direction
± X, ±Y, -Z XY*, -Z, +Z
± X, ±Y, ±Z
a)
Measuring force XY-direction
see Tab. 2.6 - Tab. 2.8
Measuring force Z-direction
7 N 4 N 5,9 N/2,0 N (LF)
Max. deflection XY
see Tab. 2.5
± 15° ± 15° * ± 15°
Max. deflection Z 10 mm -Z: 6 mm
+Z: 3 mm
5 mm
Max. acceleration
50 m/s
2
100 m/s
2
50 m/s
2 b)
Repeatability **
0,3 µm 2σ
0,3 µm 2σ
0,4 µm 2σ
Max. probing speed
3 m/min
5 m/min
2 m/min
Mass
925 g
920 g
790 g
Protection class
IP 68
Signal transmission
Radio
Frequency band 2,4000 – 2,4835 GHz
Transmission power
0 dBm
Operating range
15 m
Battery life
Saft Lithium LS 14500 (AA 3,6V)
Tool holder HSKSK-BT
BTH 50
Operating temperature
+5 °C ... +50 °C
Storage temperature
-20 °C ... +70 °C
* via spindle orientation
** Stylus L=50 mm
a)
see chap. 3.5
b)
with accessories (e.g. extension, angle): max. acceleration 10 m/s
2
Tab. 2.3