LED DEFINITION FUNCTION VALUE DESCRIPTION
P External Device key P0
P1
P2
P3
P4
No Function (Default)
A key
B key
C key
D key
U Auto Close Override U0
U1
U2
U3
U4
No Function (Default)
A key
B key
C key
D key
A. Photocell 1 Activation A.0
A.1
Function OFF (Default)
Function ON
C. Photocell 2 Activation C.0
C.1
Function OFF (Default)
Function ON
E. PCB Stop Terminal
Activation
E.0
E.1
Function OFF (Default)
Function ON
F. PB Terminal Function F.1
F.2
F.3
F.4
Open-Stop-Close-Stop (Default)
Open ONLY
Pedestrian Mode
Fire Alarm Mode
H. Open Terminal Function H.1
H.2
H.3
H.4
Open-Stop-Close-Stop (Default)
Open ONLY
Pedestrian Mode
Fire Alarm Mode
J. Over Current Sensitivity J.1
J.2
J.3
J.4
J.5
J.6
J.7
J.8
J.9
J.A
0.1 second
0.2 second
0.3 second
0.4 second
0.5 second (Default)
0.6 second
0.7 second
0.8 second
0.9 second
1 second
......CONTINUED
A
B
DC
A
B
DC