Series Ergonomic
Ergonomic 320.250 DGS
Operating instructions
Before transporting and using the machine,
please read the instructions thoroughly!
Seriové číslo / Serien Nummer / Serial Number ___________________

Table of Contents

Questions and Answers

  • B
    Brittney LopezSep 12, 2025
    Why by choke is not possible turn on my Bomar Saw?
    • S
      srileySep 12, 2025
      If you cannot turn the choke on your Bomar Saw, it may be due to: * Metal clamps between the valve and panel. Clamps must be removed and put on the shaft O-Ring about 10x2 mm. * Metal clams are in the body of valve. The valve must be cleared or changed.
  • J
    Jamie Harper MDAug 25, 2025
    How to troubleshoot Bomar Saw band drive that cannot be started?
    • M
      Mary GarciaAug 25, 2025
      If your Bomar Saw band drive cannot be started, it might be due to: * A wrongly adjusted pressure switch. Set the pressure switch according to chapter „Servicing and adjustment“. * A defective pressure switch. Replace defective parts of the pressure switch.
  • M
    Mary JenkinsAug 27, 2025
    What to do if my Bomar Ergonomic 320.250 DG machine is not possible start?
    • M
      Mario WashingtonAug 27, 2025
      If your Bomar Saw is not starting, check the following: * Ensure there is voltage in the socket. The line voltage must be checked. * Check the transfer relay (thermal protector). Each FA relay must be checked. * Verify the limit switch of saw band stretching and covers. Check the closing of the saw band stretching and covers.
  • S
    Stephen WilcoxAug 29, 2025
    Why is the cooling not active on my Bomar Ergonomic 320.250 DG?
    • J
      Juan GeorgeAug 29, 2025
      If your Bomar Saw's cooling system is not active, consider these potential issues: * Lack of cooling agent. Fill the tank with cooling agent. * Defective thermal relay. Change the thermal relay. * Broken or obstructed input hosepipe. Check the cooling circuit and cleanse the cooling system if necessary. * Defective cooling pump protection. Check the protection of the cooling pump and change it if needed. * Defective cooling pump. Replace the cooling pump.
  • E
    Elizabeth McmahonAug 30, 2025
    Why am I getting insufficient cut output from my Bomar Ergonomic 320.250 DG Saw?
    • R
      Ray WilsonAug 31, 2025
      If you're experiencing insufficient cut output with your Bomar Saw, it could be due to: * A worn saw band. Replace the saw band and keep instructions of the manufacturer on the choice. * A wrong saw band tooth system. Replace the saw band and keep instructions of the manufacturer on the choice. * Wrongly set down feed and speed of a saw band. Set feed and speed of a saw band according to values published by saw band manufacturer.
  • A
    Andrew WareSep 1, 2025
    What causes cracked saw bands on a Bomar Saw?
    • R
      ryanjordanSep 1, 2025
      If your Bomar Saw bands are cracking, it may be due to: * Wrong adjusting geometry in the stretching wheel. Adjust distance band from recess wheel c.2 mm according to operating instructions. * Hard metal plates of circuit saw band are not adjusting. Hard metal plates of circuit saw band must be adjusting according to operating instructions. * Guiding cubes are not adjusting (bearings + hard metal circuit). Guiding cubes must be adjusting (bearings + hard metal circuit) according to operating instructions. * Bearings of guiding cubes are used (rolling elements are damaged or outside ring of bearing has conical form). Bearings of guiding cubes must be replaced. Bearings must be adjusting according to operating instructions.
  • J
    Jose MccannNov 20, 2025
    Why is my Bomar Ergonomic 320.250 DG cutting at a slant?
    • M
      Molly StoneNov 20, 2025
      If your Bomar Saw's cut is slanting, it could be due to several reasons: * The hard metal guides may be wrongly adjusted. In this case, set them according to the chapter „Servicing and adjustment“. * The hard metal guides may be worn, which requires replacement according to the chapter „Worn pieces replacement“. * The cubes of the saw band guiding may be wrongly adjusted. Set them according to the chapter „Servicing and adjustment“. * The bearings of the saw band guiding may be worn, which requires replacement according to the chapter „Worn pieces replacement“. * The swarf brush may be wrongly adjusted. Set it according to the chapter „Servicing and adjustment“. * The swarf brush may be worn, which requires replacement according to the chapter „Worn pieces replacement“. * Th...
  • T
    Thomas HortonNov 25, 2025
    Why does my Bomar Ergonomic 320.250 DG Saw band have a short lifetime?
    • Z
      Zoe FisherNov 25, 2025
      If you're experiencing a short lifetime of the saw band on your Bomar Saw, consider the following: * Insufficient saw band stretching. Increase the tightening of the saw band and set the scanner of saw band tightening according to chapter „Servicing and adjustment“. * A worn swarf brush. Check the swarf brush condition and replace it if excessively worn, as described in chapter „Worn pieces replacement“. * A wrongly adjusted swarf brush. Check the swarf brush adjustment and set it according to chapter „Servicing and adjustment“. * An over stretched saw band. Lower the stretching of the saw band and set the limit switch of the saw band stretching according to chapter „Servicing and adjustment“. * Wrongly adjusted hard metal guides. Check the adjustment of the hard metal guides an...
  • P
    Phillip MartinezSep 12, 2025
    What causes the electric motor and pump to be without voltage on my Bomar Ergonomic 320.250 DG?
    • B
      brittney78Sep 12, 2025
      If the electric motor and pump are without voltage and there is no voltage between the contactor and thermal protector on your Bomar Saw, it could be due to: * A wrong contactor. Replace the contactor of the engine.
  • M
    Michael MorrisSep 7, 2025
    What to do if, when cut is finished, the frame is not raising of Bomar Saw?
    • D
      Daniel RushSep 7, 2025
      If your Bomar Saw frame is not raising when the cut is finished, check the following: * The bottom limit switch may be adjusted wrong. The bottom limit switch must be adjusted according to chapter ADJUSTING. * There may be an error in the hydraulic (pneumatic) ring. HYTOS (BOSCH) is not acting to frame uplift. Check the function of the magnetic valve, ensure the valve is closed, and verify the voltage of clamps and inductor.

Summary

Ergonomic 320.250 DGS Operating instructions

Service and information

Provides direct contact details for BOMAR, including address, phone, fax, and email.

Safety notes

Comprehensive safety guidelines for operating and maintaining the band saw.

Machine documentation

Details regarding technical specifications, diagrams, and installation procedures.

Machine control

Instructions on operating the machine's main switch, control elements, and cutting functions.

Machine service

Procedures for maintenance, adjustments, lubrication, and replacement of worn parts.

Troubleshooting

Guides for diagnosing and resolving mechanical and electrical problems.

Schematics

Electrical and hydraulic diagrams for understanding the machine's systems.

Drawing assemblies for spare parts order

Exploded views and parts lists for ordering replacement components.

Bomar Ergonomic 320.250 DG Specifications

General IconGeneral
BrandBomar
ModelErgonomic 320.250 DG
CategorySaw