CARING FOR THE ROLLERS
After an extended period of operation, you may
start hearing unwanted noise created by the rollers
in the water base. Use the provided care oil to lubri-
cate the rollers as needed.
1. Take o the front cover.
2. Remove the care oil in the cover.
3. Apply 1 drop of care oil directly to each of the
holders.
PARTICLE SENSOR
The particle sensor detects the amount of dirt in the
air in the room by analyzing a passing air flow. Over
time, dirt can accumulate and aect measuring ac-
curacy.
The flap over the particle sensor has to be
closed during operation to ensure the mea-
surement is correct. It should only be opened to
clean the sensor.
1. Clean the sensor lens using a damp cotton swab.
2. Dry the sensor with a dry cotton swab.
ASSEMBLING THE APPLIANCE
Once cleaning is complete, you can put the BONECO
H700 back together. When doing so, pay attention
to how the AH700 evaporator mat fits.