EasyManuals Logo

BONFIGLIOLI Vectron Syn10 S220 03 AF User Manual

BONFIGLIOLI Vectron Syn10 S220 03 AF
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #35 background imageLoading...
Page #35 background image
31
31
Function F_
Function Description
Unit Range
Factory
setting
Page Note
Reverse Lock-Out
22 0: REV run
1: REV run Lock-Out
1 0 ~ 1 0 40
Momentary power
loss
23 0: enabled
1: disabled
1 0 ~ 1 0 41
Auto restart 24 Number of Auto-restart times 1 0 ~ 5 0 41
Factory setting
25 010: Constants initialization to 50Hz system
020: Constants initialization to 60Hz system
42 *2
SP2 frequency 26 SP2 frequency 0.1Hz 1.0~200Hz 20 42
SP3 frequency 27 SP3 frequency 0.1Hz 1.0~200Hz 30 42
Direct start
28 0:enable
1:disable
1 0 ~ 1 1 42 *4
Software version 29 CPU program version 42
Fault Log 30 Fault log for three faults. 42
NOTE:
*1: Indicate this parameter can be adjusted during running mode.
*2: Please refer to F_25.
*3: If the setting range is above 100, the setting unit becomes 1.
*4: New function for CPU version v2.1 and above
Parameter function description
F_00 Factory adjustment parameter. Do not change.
F_01 : Acceleration time = 0.1 ~ 999 sec
F_02 : Deceleration time = 0.1 ~ 999 sec
1. Acceleration / Deceleration time calculation formula:
Setting Frequency Accelerate time = F_01 x
50 Hz
Setting Frequency Decelerate time = F_02 x
50Hz
F_01 F_02
Hz
Time

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BONFIGLIOLI Vectron Syn10 S220 03 AF and is the answer not in the manual?

BONFIGLIOLI Vectron Syn10 S220 03 AF Specifications

General IconGeneral
BrandBONFIGLIOLI
ModelVectron Syn10 S220 03 AF
CategoryController
LanguageEnglish

Related product manuals