EasyManua.ls Logo

Bonnet B1A9S+50EBE - Gas Flow Rates and Power; TABLE of JETS and Air Adjustments

Default Icon
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 20 3BE390845NI – 01/12
BONNET GRANDE CUISINE
Registered office:
Rue des Frères Lumière - Z.I Mitry Compans
F-77292 MITRY MORY Cedex
ORIGINAL GAS
(or new gas)
NEW GAS
(or original gas)
COUNTRIES
Gas P(mbar)
Gas P(mbar)
CATEGORY
NECESSARY &
AUTHORISED
OPERATIONS
Austria
G 20 20 G 30 or G 31 50 CI - RA
Switzerland
G 30 50 G 31 50
II
2H3B/P
None
Finland
G 30 30 G 31 30 None
Sweden - Denmark
I
3B/P
Belgium
G 20 20 G 25 25 None
G 20 or G 25 20/25 G 31 37
II
2E+3P
CI - RA
G 30 28-30 G 31 37 I
3+
CI - RA
G 20 20 G 25 20 CI - RA
G 20 or G 25 20 G 30 or G 31 50 CI - RA
G 30 50 G 31 50
II
2ELL3B/P
None
G 20 20
G 25 20
Germany
G 30 50
G 31 50 I
3P
CI
Change of
category (see *)
Ireland - Portugal
G 20 20 G 31 37 II
2H3P
CI - RA
United kingdom
G 30 28-30 G 31 37 CI - RA
Greece -
Switzerland
I
3+
Italy
G 30 28-30 G 31 37 I
3+
CI - RA
Spain
G 20 20 G 31 37/50 CI - RA
G 31 37 G 31 50
II
2H3P
CI - RA
G 30 30 G 31 30 I
3B/P
None
France
G 20 or G 25 20/25 G 30 or G 31 50 CI - RA
G 20 20 G 25 25 None
G 30 50 G 31 50
II
2E+3B/P
None
G 20 or G 25 20/25 G 31 37/50 CI - RA
G 31 37 G 31 50
II
2E+3P
CI - RA
G 30 28-30 G 31 37 I
3+
CI - RA
G 20 20 G 30 or G 31 50 CI - RA
G 30 50 G 31 50
II
2E3B/P
None
Luxemburg
G 20 20 G 31 50 II
2E3P
CI - RA
G 30 28-30 G 31 37 I
3+
CI - RA
Netherlands
G 25 25 G 30 or G 31 30 CI - RA
G 30 30 G 31 30
I
2L3B/P
None
G 25 25 G 31 50 II
2L3P
CI - RA
Norway
G 30 30 G 31 30 I
3B/P
None
* Change of category to be undertaken only under our responsibility or that of our local agent.
5.3 GAS FLOW RATES AND POWER
See Paragraph 1: TECHNICAL CHARACTERISTICS (Installation manual)
5.4 TABLE OF JETS and air adjustments
NOTE:
- The burners referred to as "main burner" are simple tubes (BP: Main Burner).
- The burners referred to as "secondary burner" are burners equipped with the inter-ignition ramp (BS:
Secondary Burner).

Related product manuals