Fan 1500, Fan 1500 DH 11
Risk of fatal injury from electric shock!
Touching live electrical parts may result in electric shock
The bathroom extractor fan is designed for permanent indoor connection,
for xed electrical installation, which must be equipped with means/devices
for total contact breakage in order to ensure complete separation under
overvoltage conditions of category III according to the regulations for such
installation�
The bathroom extractor fan is designed for installation at a substantial
height, i�e� 2,3 m above the oor� Installation - only in accordance with the
descriptions and guidelines in this manual, in particular with regard to the
required installation position, by inserting the power cord into the housing
Measures shall be taken to prevent gases from escaping from open smoke duct or other open ame
equipment into the room�
Unauthorised changes or modications to the equipment are not permitted
Before installing the equipment, check the load-bearing capacity of the structure to which it is to be
mounted, as improper mounting can lead to damage or destruction of the equipment and can pose
a risk to persons in the vicinity of the equipment in the following situations�
The appliance may become dangerous
if used improperly or if installed by unqualied personnel.
3 APPLICATION AND OPERATING CONDITIONS
Bathroom extractor fans are designed to transport normal or slightly dusty air (particle size <10 μm)
of low aggressiveness and humidity in temperate climates according to and within their limits
of performance�
The appliance is designed only for continuous operation in a building if there is no access
to the power supply line�
The maximum temperature of the medium handled by the bathroom extractor fan and the maximum
ambient temperature are +40°C�
The exhaust fan is IP4 and protection class II device if it is installed in accordance with Appendix
1 (Fig� 5) in the wall� The fan is not designed for ceiling installation�
The bathroom extractor fan must be operated according to its intended use and in accordance
with the data provided on the rating plate�
The bathroom extractor fan must be connected to the building mains (recessed electrical installation)
with one of the following power cable: NYM-O 2x1,5 mm
2
; NYM-O 3x1,5 mm
2
; NYM-J 3x1,5 mm
2
,
depending on the fan version - see point 6� If a cable with more wires has to be used,
e�g� NYM-J 4x1,5mm
2
, the outer diameter of the cable must not exceed 14mm�
The bathroom extractor fan cannot be used to circulate air with the following characteristics:
-viscous contaminants prone to deposition in the bathroom extractor fan,
-corrosive contaminants which may degrade the bathroom extractor fan,