14 Fan 1500, Fan 1500 DH
Check the sealing of the connection cable�
-The connection cable must be protected in such a way that, in the event of ooding,
under no circumstances can water reach the live parts�
Put on the electrical cover (2) and then screw it in with screws (3)�
Attach the front panel (1) which acts as protection against touching moving parts�
ATTENTION! Hazard of crushing ngers with the rotating fan rotor!
Install the guard against the direct touch of moving parts before starting!
7 FIRST START OF THE DEVICE
The rst start may only take place after all safety precautions have been checked and risks have been
eliminated� After the bathroom extractor fan start-up, check that it runs steadily and the air is handled
eciently (out of the room and through the exhaust duct to the outside)�
The bathroom extractor fan may only be used with the front panel, which provides protection against
contact with moving parts�
The installer is responsible for compliance with the applicable standards and may be held liable for
accidents resulting from the absence of safety devices�
8 ELECTRICAL CONNECTIONS
The electrical connection and start-up may only be carried out by qualied personnel who are
qualied to perform electrical work
• Always follow the applicable standards, safety regulations and technical requirements specied by
the power company!
The type of mains system, voltage and frequency must match the data on the rating plate of the
bathroom extractor fan�
• For bathroom extractor fans with stop delay time, the minimum voltage at the T terminal that starts
the stop delay countdown or starts the exhaust fan is 130V AC�
9 DIMENSIONS
The dimensions of the models are listed on the packaging and Figure 6
10 MAINTENANCE AND CLEANING
Maintenance
Observe the safety and OHS regulations during all maintenance work�
Before servicing the bathroom extractor fan, disconnect it from the mains and secure it against
inadvertent operation!
The bathroom extractor fan ventilation ducts must be clear of foreign bodies: hazard of injury by
objects blown out at a high speed!