Bosch AMAX 2100 - User Manual

Bosch AMAX 2100
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
AMAX panel
AMAX panel 2100 | AMAX panel 3000 | AMAX panel
3000 BE | AMAX panel 4000
en Operation Manual

Table of Contents

Other manuals for Bosch AMAX 2100

Questions and Answers

  • A
    Amber SchmidtAug 19, 2025
    What to do if there is no display on the keypad after power up for Bosch Security System?
    • T
      tatetylerAug 19, 2025
      If your Bosch Security System keypad isn't displaying anything after powering up, it could be due to a failure in the AC power or battery fuses, or abnormal RBGY wiring. Check that the AC power and battery fuses are properly connected and functioning correctly. Also, try reconnecting the RBGY wiring.
  • R
    Rodney SimpsonAug 27, 2025
    What to do if my Bosch AMAX 2100 keypad is not responding?
    • R
      Robert FloydAug 27, 2025
      If your Bosch Security System keypad is unresponsive and emits a wrong tone when you press any key, it could be due to: * Abnormal RBGY wiring. * The keypad being locked after entering incorrect passwords multiple times. * An incorrect jumper setting when using multiple keypads. To fix this, try reconnecting the RBGY wiring. If the keypad is locked, wait for 3 minutes before trying again. If you are using multiple keypads, reset the jumper referring to the keypad address settings information.
  • J
    Jenna SmithSep 3, 2025
    How to fix a constant on zone indicator on a Bosch AMAX 2100?
    • W
      William JordanSep 4, 2025
      If a zone indicator on your Bosch Security System is constantly on, it could be due to incorrect zone wiring, a malfunctioning detector, or the zone EOL resistor not being correctly connected to the end of the detector. Try re-entering the zone wiring, resetting the detector, and ensuring the zone EOL resistor is correctly connected to the end of the detector.
  • U
    uwarnerNov 11, 2025
    Why is the fault indicator constantly on or flashing on my Bosch AMAX 2100 Security System?
    • C
      Connie HensleyNov 11, 2025
      If the fault indicator on your Bosch Security System is constantly on or flashing, there could be several reasons: * The date and time may not be set. * The backup battery might not be connected or have a voltage lower than 12V. * The alarm siren may not be connected. * The telephone number may be incorrectly set. * The telephone network may not be connected. * The tamper switch may not be connected. * An external module required for programming might not be connected. To resolve this, set the date and time, connect the battery or ensure its voltage is over 12V, connect the alarm siren (or substitute it with a 1K resistor), correctly set the telephone number, connect the telephone network, connect the tamper switch or a short circuit jumper, and connect any necessary progra...

Bosch AMAX 2100 Specifications

General IconGeneral
SeriesAMAX
No of Keypads4
No of Users32
Communication FormatsContact ID, SIA
Operating Temperature-10°C to +55°C
Protection ClassIP30
Storage Temperature-20°C to +55°C
Relative Humidity93% non-condensing
Event Buffer256 events