en | Options Control Panels
2019.06 | 07 | F.01U.307.371 Bosch Security Systems B.V.
32.4 Cross points
Points can be assigned to cross point groups. When a point in a cross
point group detects an alarm, the control panel starts the cross point
timer. If a second point in the same cross point group detects an alarm
while the cross point timer is active, the control panel sends alarm
reports for both points.
If a single cross point detects an alarm and stays in alarm throughout
the cross point timer, the control panel sends an alarm report only for
that point. If a single point in a cross point group detects an alarm and
restores while the timer is still active, the system sends an unverified
event for that point. A second alarm on the first point does not create
an alarm event, but rather an unverified event.
Cross points are:
enabled on my system.
disabled on my system.

Table of Contents

Other manuals for Bosch B4512

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch B4512 and is the answer not in the manual?

Bosch B4512 Specifications

General IconGeneral
Control Panel TypeHybrid
Wired Zones8
Outputs2
Programmable Outputs2
Onboard EthernetYes
Cellular CommunicationOptional
SeriesB Series
Partitions2
TypeControl Panel
ModelB4512
ManufacturerBosch
Input Voltage16.5 VAC
Communication FormatsContact ID, SIA
Power Supply16.5 VAC
Backup Battery12 V, 7 Ah
Operating Temperature0°C to +50°C
Weight1.5 kg
CompatibilityBosch accessories

Related product manuals