Control Panels Keypad Installer menu | en 127
Bosch Security Systems, Inc. Installation and System Reference Guide 2016.06 | 08 | F.01U.303.996
25 ______________________________________________________________________
26 ______________________________________________________________________
27 ______________________________________________________________________
28 ______________________________________________________________________
29 ______________________________________________________________________
30 ______________________________________________________________________
31 ______________________________________________________________________
32 ______________________________________________________________________
SMS Phone #
B91x/B92x keypads configuration of SMS Phone #
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [1] Program > [1] Reporting > [4] Personal Note. The keypad shows the phone
number or email address of the selected personal notification destination.
3. Use [PREV] or [NEXT] to scroll though the list of personal notification destination, and go
to the destination you want to program.
4. Press [ENTER] to edit the phone number or email address.
5. Delete existing characters, if necessary, and then enter the new characters.
6. Press [ENTER] to save the phone number or email address.
7. When the keypad shows Parameter Saved, escape from the menu.
B93x/B94x keypads configuration of SMS Phone #
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [1] Program > [1] Reporting > [4] Personal Note. The keypad shows the phone
number or email address of the selected destination.
3. Use /[PREV] or /[NEXT] to scroll though the list of destinations and go to the
destination you want to program.
4. Press [Edit] to edit the phone number or email address.
5. Delete existing characters, if necessary, and then enter the new characters.
6. Press [Save] to save the phone number or email address.
7. When the keypad shows Parameter Saved, escape from the menu.
20.1.5 [2] Network > [1] Ethernet > (choose the bus module or on-board) > [1]
Module Parameters menu
You can use DCHP/AutoIP or UPnP for Ethernet communication with the on-board Ethernet or
a B426. In this menu, you can enable and disable these protocols.
Default Module settings
DHCP/AutoIP Enable Yes Yes/No
UPnP Enable Yes Yes/No
IPv4 Address 0.0.0.0 _______________________________
IPv4 Subnet Mask 255.255.255.255 _______________________________
Default Gateway 0.0.0.0 _______________________________