28.3 Schedule (SKEDs)
A SKED is a function programmed to be performed automatically
at a scheduled time by your security system. You can change the
scheduled time for SKEDs, disable a SKED to prevent it from
automatically happening, or restart a previously disabled SKED.
Contact your security company to determine what SKEDs they
programmed for your system.
Selecting a SKED to change:
1. Open the Main menu.
2. Use [NEXT] to go to the Settings menu option, and press
[ENTER], or simply press [5].
3. Use [NEXT] to go to the Schedule menu option, and [ENTER],
or simply press [3].
4. Enter your passcode and press [ENTER].
5. Use [PREV] or [NEXT] to scroll through the list of SKEDs. The
keypad indicates whether a SKED is enabled, disabled, or not
yet programmed.
6. With the SKED you wish to enable showing, press [ENTER].
7. Continue to Enabling a disabled SKED or Disabling a enabled
SKED.
Control Panels B92x/B91x Settings menu | en 191
Bosch Security Systems, Inc. 2015.01 | 02 | F.01U.307.371

Table of Contents

Other manuals for Bosch B9512G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch B9512G and is the answer not in the manual?

Bosch B9512G Specifications

General IconGeneral
ModelB9512G
ManufacturerBosch
CompatibilityBosch Security Systems
Number of Zones599
Keypads32
Communication FormatsContact ID, SIA
Input Voltage16.5 VAC
Battery Backup7 Ah
Operating Temperature0°C to +49°C (32°F to +120°F)