1 689 979 943 2012-10-24| Robert Bosch GmbH
Maintenance | BAT 415 | 17 en
5. Maintenance
! Work on electrical equipment is only to be per-
formed by persons with sufficient knowledge and
experience of electrical systems!
5.1 Cleaning
! Do not use abrasive cleaning agents and coarse
workshop cloths!
¶ The housing and the LCD are only to be cleaned
using a soft cloth and neutral cleaning agents.
The BAT 415 is subject to the European
directive 2002/96/EC (WEEE).
Dispose of used electrical and electronic
devices, including cables, accessories and
batteries, separately from household waste.
¶
Make use of the local return and collection
systems for disposal.
¶ Proper disposal of the BAT 415 prevents
environmental pollution and possible
health hazards.
5.2 Spare and wearing parts
Description Order Number
Charging lead with PVC insulation
>)
1 684 460 235
Mains connecting lead
<)
1 684 460 236
<)
Wearing part
5.3 Disposal
6. Technical data
Properties Value, Range
Charging current Max. 15 A
Charging lead length
*)
2 m
Charging lead cross-section 4.0 mm
2
Power consumption 280 W
Weight approx. 4 kg
Characteristic charging curve IUIaIaI
Final charge voltage at setting
> 15 °C
14.0 V
Voltage limit for secondary
charging at setting > 15 °C
14.4 V
Final charge voltage at setting
< 15 °C
14.4 V
Voltage limit for secondary
charging at setting < 15 °C
14.8 V
Back up / buffer mode 12.0 V maximum 3 A
13.5 V maximum 15 A
Function temperature range 0 °C to 40 °C
Mains voltage / frequency 230 V, 50/60 Hz
Mains fuse H 250 T 3.15 A
Nominal battery voltage 12 V
Protection type (DIN 40050) IP 20
Class of protection
(DIN 40530)
II
Dimensions (W x H x D) 260 x 160 x 250 mm
Work-related noise emission
value (Lpa)
≤ 70 dB(A)
Interference emission level DIN 40839 Interference emissi-
on level I
*)
The charging leads may not be changed!