Commercial Series TriTech and TriTech AM
detectors
en
Installation manual

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Bosch CDL2-15H and is the answer not in the manual?

Bosch CDL2-15H Specifications

General IconGeneral
Coverage360°
TypeMotion Detector
Detection TechnologyPassive Infrared (PIR) and Microwave
Detection Range15 meters
Alarm ContactNormally Closed (NC)
Housing MaterialPlastic

Summary

Safety Information

Installation Considerations

Bracket Use and Performance Impact

Advises on bracket use, catch performance, and regulatory certification.

Installation Procedures

Self-Locking Cam Mechanism

Explains the operation of the self-locking cam for opening and closing the detector.

Install Options: Detector Base and Brackets

Describes options for installing the detector using the base or brackets.

Wiring Guide

Wiring Overview: TriTech AM Terminal Block

Overview of the TriTech AM terminal block and its connections.

Wiring Overview: TriTech Terminal Block

Overview of the TriTech terminal block and its connections.

Input Power Terminals

Details requirements for connecting power to the detector.

Alarm Terminals Functionality

Explains the normally closed relay contacts for alarm signals.

Tamper Terminals Functionality

Explains the tamper switch functionality.

Trouble Terminals Functionality

Explains the normally closed relay contacts for trouble signals.

EOL Resistors Overview

Introduces the use of built-in resistors for loop wiring.

Alarm Resistors (Dip Switch Section 1)

Details using dip switches for alarm resistor configuration.

TriTech AM EOL Resistor Configuration

Explains ON/OFF switches for single/dual EOL resistor configuration in TriTech AM.

Tamper;EOL Resistors (Dip Switch Section 2)

Details using dip switches for tamper/EOL resistor configuration.

EOL Resistor Loop Combinations

Discusses combinations of EOL resistors for loop wiring.

Single EOL Loop - Alarm and Tamper (TriTech)

Illustrates wiring for single EOL loop with alarm and tamper for TriTech.

Single EOL Loop - Alarm and Tamper (TriTech AM)

Illustrates wiring for single EOL loop with alarm and tamper for TriTech AM.

Double EOL Loop - Alarm and Tamper (TriTech)

Illustrates wiring for double EOL loop with alarm and tamper for TriTech.

Double EOL Loop - Alarm and Tamper (TriTech AM)

Illustrates wiring for double EOL loop with alarm and tamper for TriTech AM.

Double EOL Loop - Alarm;Tamper with Trouble (TriTech)

Illustrates wiring for double EOL loop with alarm, tamper, and trouble for TriTech.

Configuration Options

7.6 Walk Test Procedure and Adjustments

Steps for performing a walk test to check and adjust detector coverage.

Troubleshooting Guide