CM751B
Installer Reference Guide
6
Bosch Security Systems 5/13 CM751BIRG FTR1.0
Figure 9: Uploaded Dierences
Move to the Devices tab and select detail view, then scroll
down or use the navigation tree to locate the Ethernet
Module section. Right click on the Physical Address (MAC)
eld and select the MAC address which is in the database.
This should match the MAC Address of the module you
are installing.
Review any other highlighted dierences and then save
the changes to the database.
Figure 10: MAC Address Selection
Go to the Ethernet Module section in the Devices tab and
uncheck the “Obtain IP Address Automatically” option
then enter the IP Address of the CM751B, the Subnet Mask
and the Default Gateway in the elds provided and then
save the changes.
Figure 11: Subnet Mask and Default Gateway Entry
Step 3 - Conguring the Panel for IP Reporting
Before you will be able to congure the panel for IP
reporting you will need to make sure you have the rel-
evant information from the control room. The following is
required,
1. IP Address for the base stations IP Receiver.
2. IP Port for the base stations IP Receiver.
3. Poll Rate.
4. Acknowledge Wait Time.
5. Reporting Format.
6. If Conettix NNC Anti Replay format is being used,
you will need the base station allocated NNC
Number.
7. If encryption is required you will need the base
station allocated Encryption Key.
Move to the Reporting Route section on the Comms tab
and set the transmission format to Ethernet format for
Destination 1, 2 or both as required.
Figure 12: Conguring the Transmission Format