CM751B Installer Reference Guide
9
Bosch Security Systems 5/13 CM751BIRG FTR1.0
Summary of IP Program Locations for the Solution 144 Panel
Solution 144 IP Programming Options
Description Default Menu Number
Comms > Reporting MENU 5-4
TX Format
Dest 1 Contact ID MENU 5-4-0
Dest 2 Contact ID MENU 5-4-1
Comms > IP Reporting MENU 5-6
Base Station IP Address
Dest 1
Dest 2
000.000.000.000
000.000.000.000
MENU 5-6-0
Base Station Port #
Dest 1
Dest 2
07700
07700
MENU 5-6-1
Base Station Poll Rate
Dest 1
Dest 2
30 Seconds
30 Seconds
MENU 5-6-2
Acknowledge Wait Time
Dest 1
Dest 2
10 Seconds
10 Seconds
MENU 5-6-3
IP Format
Dest 1
Dest 2
Conettix NNC
Conettix NNC
MENU 5-6-4
IP Retry Count
Dest 1
Dest 2
03 Times
03 Times
MENU 5-6-5
IP Encryption Key
Dest 1
Dest 2
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
MENU 5-6-6
Conettix NNC
Dest 1
Dest 2
00000000
00000000
MENU 5-6-7
SIA IP Account
Dest 1
Dest 2
0000000000000000
0000000000000000
MENU 5-6-8SIA IP Account Prex
Dest 1
Dest 2
000000
000000
SIA IP Receiver Prex
Dest 1
Dest 2
000000
000000
User Name
Dest 1
Dest 2
MENU 5-6-9
Password
Dest 1
Dest 2
Comms > IP Remote Access MENU 5-7
IP RAS Address
Installer
User
000.000.000.000
000.000.000.000
MENU 5-7-0
IP RAS Port #
Installer
User
07701
07701
MENU 5-7-1
IP RAS Options Various MENU 5-7-2
IP RAS Lockout Time 60 Seconds MENU 5-7-3
IPRS Address (Do Not Change) 202.129.083.058 MENU 5-7-5
IPRS Port (Do Not Change) 07703 MENU 5-7-6
Devices > Ethernet Module MENU 6-6
Module IP Address 000.000.000.000 MENU 6-6-0
Subnet Mask 000.000.000.000 MENU 6-6-1
Default Gateway 000.000.000.000 MENU 6-6-2
Module MAC Address 00.00.00.00.00.00 MENU 6-6-3
Ethernet Module Options Various MENU 6-6-9
Table 1: Solution 144 Program Locations