10 en | Installation Conettix Cellular Communicators
2020.02 | 04 | F.01U.345.070 Installation Manual Bosch Security Systems B.V.
Notice!
For proper spacing, the antennas should be placed at either corner of the enclosure.
Figure3.4: B444-A/B444-V cable connection
3.3 Install the communicator
Control panel/universal dual path communicator installation
1. Put the support leg into the support hole labeled X. Refer to Figure 3.3.
2. Align the PCB metal contacts with the on-board connector.
3. Push the module into place. The retention clip snaps closed and secures the module in
place.