Conettix DX4020 | Installation Guide | 7.0 Control Panel Programming
16 Bosch Security Systems, Inc. | 1/09 | F01U045288-05
7.0 Control Panel Programming
Table 7 lists available documentation for DX4020 to control panel programming.
Table 7: Compatible Control Panel Documentation
Control Panel Documentation
D9412GV2/D7412GV2 D9412GV2/D7412GV2 Program Entry Guide (P/N: F01U003636)
D7212GV2 D7212GV2 Program Entry Guide (P/N: F01U003804)
D9412G/D7412G D9412G/D7412G Program Entry Guide (P/N: 47775)
D7212G D7212G Program Entry Guide (P/N: 4998138538)
D9112 D9112 Program Entry Guide (P/N: 74-06145-000)
DS7240V2/DS7220V2 DS7200V2-EXP Installer's Guide (P/N: 4998153893)
DS7400Xi DS7400Xi V4-EXP Release Notes (P/N: 4998154793)
FPD-7024 FPD-7024 Operation and Installation Guide (P/N: F01U008458)
Easy Series V3+ Easy Series System Reference Guide (P/N: F01U087835)
8.0 Specifications
Table 8: Specifications
Dimensions
7.6 cm x 12.7 cm (3 in. x 5 in.)
Current Draw
110 mA, maximum, 10 Base-T
135 mA maximum, 100 Base-T
Operating Voltage
12 VDC nominal
Connectors
Control Panel: Option or data bus terminal strip
LAN/WAN: RJ-45 Modular Jack (Ethernet)
Ethernet Cable
Category 3 or better unshielded twisted pair
Maximum Length: 100 m (328 ft)
Interface
IEEE 802.3
Control Panel Firmware
GV2 Series: D9412GV2, D7412GV2, D7212GV2
All versions
G Series: D9412G, D7412G, D7212G,
6.3 or later
9000 Series: D9412, D7412, D7212, D9112
6.3 or later
DS7220V2, DS7240V2 2.xx or later
DS7400XiV4-EXP 4.10 or later
FPD-7024 All versions
Compatibility
Easy Series V3+ 3.0 or later
Default IP Address
0.0.0.0 (DHCP Mode)