Operation
63
Climate Room Control – 6721841498 (2022/04)
Press the TIMER or key to confirm the entry.
The selection jumps to the time.
Press or hold the . or / key to set the time.
Press the TIMER or key to confirm the entry.
To toggle between 12- and 24-hour display:
Press/keep the TIMER and DAY OFF keys pressed
simultaneously for several seconds.
5.3 Setting main operating mode
Depending on the indoor unit and configuration of the wired
room controller, not all operating modes may be available.
Turn unit on/off
▶Pressthe K key to switch the device on or off:
The unit starts in the set operating mode or switches off. To
protect the unit it can only be switched back on after some
time has passed.
Settings can also be made when the appliance is switched off.
The device saves the settings, and also retains them in the
event of a power failure.
After it has been switched off, the unit remains in standby
mode. An automatic energy saving mode is enabled in standby
mode due to intelligent On/Off technology (1 W standby).
Following a power failure the unit restarts automatically. This
can lead to conflicting readings on the displays which are
resolved automatically during operation.
Automatic mode
In automatic mode, the unit switches automatically between
heating, cooling, fan and dehumidification mode, depending
on the set temperature.
Press the M key repeatedly until appears on the
display.
Press the . or / key to set the required temperature.
The fan speed cannot be adjusted in automatic mode.
Cooling mode
Press the M key repeatedly until appears on the display.
Press the key until the required air speed is reached.
Press the . or / key to set the required temperature.
Dehumidification mode
Press the M key repeatedly until appears on the display.
Press the . or / key to set the required temperature.
The fan speed cannot be adjusted in dehumidification mode.
Heating mode
Press the M key until appears on the display.
Press the . or / key to set the required temperature.
Press the key until the required air speed is reached.
If the outside temperature is very low, the heating capacity of
the air conditioning system may not be sufficient. We
recommend connecting additional heat sources.
Fan (Only) Mode
Press the M key repeatedly until appears on the display.
Press the key until the required fan speed is reached.
AUTO can be selected to enable automatic control.
The temperature cannot be adjusted or displayed in fan mode.
5.4 Setting the room temperature
Press the . or / key to set the desired room temperature.
The setting is applied shortly afterwards.
The temperature cannot be adjusted in Fan Mode.
5.5 Setting timer
5.5.1 One-time ON/OFF timer
Press the TIMER key repeatedly until the corresponding
symbol appears.
–ON timer: ON DAY
OFF timer: OFF DAY
ON and OFF timer: ON+OFF DAY
▶Confirm with key.
The clock display starts flashing.
Press the . or / key to set the desired ON/OFF time.
Press the key again to save the setting.